Model LVG-102, 103, 104
1-4
Problem
Cause
Correction
HEATING OF SHORTENING SECTION (Continued)
•
Drain valve open
•
Close drain valve
(Continued)
•
Faulty temperature probe
•
Replace temperature probe
•
Faulty gas valve
•
Check gas valve
Oil heating
too slow
• Low gas pressure
• Have gas pressure checked
• Wire(s) loose
• Tighten
• Burnt or charred wire
• Replace wire and clean
connection
connectors
Oil overheating
• Programming wrong
• Check temperature setting
in the program mode
• Faulty PC board
• Replace control board if heat
indicator stays on past ready
temperature
• Faulty temperature probe
• Check probe calibration and
replace if temperature is off + 5
degress
• Faulty gas valve
• Check gas valve
Oil will not heat