Model LVG-102, 103, 104
7-7
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
3. Using a 3/8” socket, remove 2 screws securing the burner
jet bracket and remove bracket.
4. Pull both burner jets from unit.
5. Using a 1/2” wrench, remove nut on compression fitting,
and remove the temperature probe from the vat.
6. Using terminal extractor, remove probe terminals from
connector and remove probe from unit.
7-6. TEMPERATURE PROBE
REPLACEMENT
(Continued)
Aug. 2008