Model LVG-102, 103, 104
7-11
7-7. SOLENOID VALVES
(Continued)
4. Remove elbow and fittings from solenoid stem assembly,
and attach them to new solenoid, using pipe sealent on the
threads.
5. Reattach the conduit to new solenoid, threading the wires
through the conduit.
6. Reattach the solenoid assembly to the fryer.
7. Reattach the conduit to fryer and connect the wires to the
fryer using wire nuts.
8. Replace rear side panels or rear panels and reconnect power
to the fryer.
7-8. DRAIN VALVE
ACTUATORS
Each vat drain valve is opened and closed by an actuator, so if
the oil won’t drain or pump back into the vat, the actuator may
be faulty.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Access faulty actuator by removing a side panel or opening
doors, depending upon the location of the actuator.
2. Push-out the retaining pins in the front and rear of actuator.
3. Disconnect the wires.
4 Install new actuator in reverse order, and reconnect power
to the fryer.
Aug. 2008
Содержание LOV LVG-102
Страница 2: ...Model LVG 102 103 104 2...
Страница 21: ...Model LVG 102 103 104 3 6...
Страница 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Страница 89: ...Model LVG 102 103 104 A 2 May 2016...
Страница 90: ...Model LVG 102 103 104 A 3 May 2016...
Страница 91: ...Model LVG 102 103 104 A 4 May 2016...
Страница 92: ...Model LVG 102 103 104 A 5 May 2016...
Страница 93: ...Model LVG 102 103 104 A 6 May 2016...
Страница 94: ...Model LVG 102 103 104 A 7 May 2016...
Страница 95: ...Model LVG 102 103 104 A 8 May 2016...
Страница 96: ...Model LVG 102 103 104 A 9 May 2016...
Страница 97: ...Model LVG 102 103 104 A 10 May 2016...
Страница 98: ...Model LVG 102 103 104 A 11 May 2016...