![Henny Penny LOV LVG-102 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/henny-penny/lov-lvg-102/lov-lvg-102_technical-manual_2124355060.webp)
Model LVG-102, 103, 104
7-21
7-17. FILTER AND JIB LIGHTS
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove control panel.
2. Locate wires to light and cut wires.
3. Using a 13/16”, deep-well socket (see photo at left) remove
nut on the back side of panel and pull the light from the
frontof the panel.
4. Install new light with deep-well socket, connect wires with
wire nuts and reinstall the control panel.
5. Restore power to the unit.