1-4. ERROR CODES
In the event of a control system failure, the digital display
shows an error message. The message codes are shown in the
DISPLAY column below. A constant tone is heard when an er-
ror code is displayed, and to silence this tone, press any button.
Feb. 2011
DISPLAY
CAUSE
CORRECTION
“E-4”
Control board overheating
Turn switch to OFF position, then turn switch back
to ON; if display shows “E-4”, the control board is
getting too hot; check the louvers on each side of
the unit for obstructions
“E-5”
Oil overheating
Turn switch to OFF position, then turn switch back
to ON; if display shows “E-5”, the heating circuits
and temperature probe should be checked
“E-6A”
Temperature probe open
Turn switch to OFF position, then turn switch back
to ON; if display shows “E-6A”, the temperature
probe should be checked
“E-6B”
Temperature probe shorted checked
Turn switch to OFF position, then turn switch back
to ON; if display shows “E-6B”, temperature probe
should be
“E-10”
E-10A- tripped above 300F
E-10B- tripped below 300F
E-10C- tripped while cooking
E-10D- tripped <5min. of Auto Filter
E-10F- tripped during filter cycle
E-10M- tripped during melt mode
E-10Y- tripped <5min of “YES” to
“IS THE POT FULL?” prompt
Allow fryer to cool for 15-20 minutes; reset high
limit by pressing down & releasing raisedside of
the switch for the vat that is not operating; a single
reset switch is found behind the door of each well;
if high limit does not reset, high limit must be
replaced
“E-15”
Drain valve open
Clean and/or close fish vat drain valve; if clean and
closed, have drain switch continuity checked
“E-18-A”
“E-18-B”
“E-18-C”
Left level sensor open
Right level sensor open
Both level sensors open
Turn switch to OFF position, then turn switch back
to ON; If display still indicates a failed sensor,
check the connectors at the control board; check
sensor & replace, if necessory
“E-20-A”
“FAN
SENSOR
STUCK
CLOSED”
Pressure switch failure/ Wiring
problem
If fan is not running, have pressure switch
checked; should be open circuit, if no air pressure
If fan is running, wiring error
Содержание LOV LVG-102
Страница 2: ...Model LVG 102 103 104 2...
Страница 21: ...Model LVG 102 103 104 3 6...
Страница 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Страница 89: ...Model LVG 102 103 104 A 2 May 2016...
Страница 90: ...Model LVG 102 103 104 A 3 May 2016...
Страница 91: ...Model LVG 102 103 104 A 4 May 2016...
Страница 92: ...Model LVG 102 103 104 A 5 May 2016...
Страница 93: ...Model LVG 102 103 104 A 6 May 2016...
Страница 94: ...Model LVG 102 103 104 A 7 May 2016...
Страница 95: ...Model LVG 102 103 104 A 8 May 2016...
Страница 96: ...Model LVG 102 103 104 A 9 May 2016...
Страница 97: ...Model LVG 102 103 104 A 10 May 2016...
Страница 98: ...Model LVG 102 103 104 A 11 May 2016...