background image

Содержание DNCD450EGBWC

Страница 1: ...pse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire Do not install or store this appliance in any location where it could be exposed to water and or weather Save these instructions Installers Be sure to leave these instructions with the customer NOTE Installation and service of this dryer requires basic mechanical and electrical skills It ...

Страница 2: ... the appliance CONNECTING DRYER USING 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION NOTE Since January 1 1996 the National Electric code requires that the new constructions utilize a 4 wire connection to an electric dryer WARNING Only a 4 conductor cord shall be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding th...

Страница 3: ...exhaust longer than specified length will Increasethe drying times and the energy cost Reducethe dryer life Accumulate lint creating a potential fire hazard The correct exhaust installation is YOURRESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with ULlisted transition duct The HA IM...

Страница 4: ...creen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or exhausted air Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system sha...

Страница 5: ...US LENGTH I SIT DRYER I11 ON FLEXIBLE l For best drying performance 1 Slideone end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exh...

Страница 6: ...information F9 GARAGE INSTALLATION IF ALLOWED BY LOCAL CODES Dryers installed in garages must be elevated 18 inches 46cm above the floor rO7DRYEREXHAUST TO RIGHT LEFT OR BOTTOM CABINET AWARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES REM...

Страница 7: ..._WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE KIT WEIM454 i ilCHANGING DIRECTION OF DOOR OPENING OPTIONAL 1 Openthe door and removethe filler plugs oppositethe hinges With the door completely open remove the bottom screws from each hinge on the dryer face Insert these screws about half way into the TOP holes for eachhinge on the opposite side where you removed the filler plugs Apply firm...

Страница 8: ...S CAN CAUSE iMPROPER AND DANGEROUS OPERATION AFTER SERVICI NG I NSTALLATION Instructions REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY IMPORTANT PRODUCT NOTIFICATIONS Pleasego to www GEAppliences com or mail in your product registration card For questions on installation call 800 626 2000 US or 800 561 3344 Canada ...