Users Guide
Motor Setup
The Setup Speed Enable/Disable is used to manually control the speed of the Main Motor, when enabled
what ever percentage entered in the manual speed will be used as the speed reference.
Manual Speed – displays the speed reference percentage used when speed setup is enabled.
Drive Status displays if the drive is moving forward, reverse, or is off.
The Job Drive Push Button will send a signal to the drive to manually jog the drive forward.
Drive Reset is only to be used when the Fault Reset Push Button is unable to clear the Drive Fault, this
button will reboot the drive.
Speed Settings are the speed reference the main motor runs at then the press is in one of the listed
modes.