Alarm Explanations
BATCH COUNTER FULL
This fault occurs when all of the following events occur:
•
The actual batch count is greater than the preset specified on the Counter Screen
Clearing fault:
1. Press the fault reset push button; this will clear the actual count.
2. Set preset to zero to bypass this alarm.
BRAKE STOPPING TIME FAULT
This fault occurs when all of the following events occur:
•
The brake output is off
•
The actual stopping time is greater than the limit set in the SETUP Screen on the
HMI
•
The Key switch is in single or auto stroke mode
Clearing fault:
1. Check the SYSTEM SETUP screen and observe the current BRAKE STOP TIME
and the current limit
2. Press the fault reset push button
CHANNEL (1, 2, 3, 4) HIGH CAPACITY ALARM
This fault occurs when all of the following events occur:
•
The tonnage was higher than the capacity alarm setpoint
Clearing fault:
1. Verify die height
2. Press the fault reset push button
CHANNEL (1, 2, 3, 4) HIGH CAPACITY ALARM EQUALS “0”
This fault occurs when all of the following events occur:
•
The high capacity alarm setpoint is equal to zero
Clearing fault:
1. Verify and adjust the setpoint
2. Press the fault reset push button
CHANNEL (1, 2, 3, 4) HIGH TREND
This fault occurs when all of the following events occur:
•
When the current peak load has met or exceeded the high tolerance percentage or
tonnage setting from the sample tonnage.
Clearing fault:
1. Verify die height
2. Press the fault reset push button