HelmPak Press Control
26
Users Guide
Enter or Change Recipe Die Monitoring Settings
Press Blue Die Monitoring button at the bottom of the overview screen to jump to DM Recipe screen
Touch the yellow field indicated by channel select, to enter the desired channel, or use the arrow keys
Touch the Name Button select the desired name, these names need to be set in the HMI Application and
downloaded to the HMI .
Touch the Mode Button to select the mode of operation, these is explained on page 8.
Static
Cyclic
Intermittent Cycle
In Position
Intermittent In Position
Touch the Input Button select if the sensor is Normally Open or Normally Closed
Touch the Output Button to select the necessary response from the press control
Bypass – Channel is not being used
Emergency Stop – Alarm will indicate, Press will stop immediately when fault occurs
Top Stop – Alarm will indicate, Press will stop at top when a fault occurs
Warning – Alarm will indicate, but press movement will not be impaired.
Touch Angle On/Off to enter values.
Touch Intermittent Interval window to select interval count if Intermittent Mode is selected.
Press Save Changes to save settings permanently in the Recipe.