HelmPak Press Control
22
Users Guide
Shutheight Setup
The Set Initial Config button is used to setup the shutheight module for the first time, or if the module has
been replaced.
The Set Zero button is used to clear the internal offset value of the shutheight resolver module, which
should be done anytime the resolver needs to be recalibrated, for example if the coupling breaks and the
slide or resolver shaft have been moved even slightly. The Zero should be set at the maximum
shutheight, or just before the maximum limit is reached.
Set Max by moving slide position to near maximum, enter the measured distance as the maximum and
press the Set Max button.
Set Min by moving slide position to near minimum, enter the measured distance as the minimum and
press the Set Min button.
Auto Slide Adjust can be enabled or disabled from this window, and is only used when a recipe is being
downloaded.
The current position of the Slide Adjust key Switch is also displayed on this screen.