Change Active Die Monitoring Settings
Press Die Monitoring button at the bottom of the Active Overview screen to jump to Active DM screen
Touch the yellow field indicated by channel select, to enter the desired channel, or use the arrow keys.
Input Status – displays the current status of the selected channels DM sensor.
Touch the Name Button to select the desired name, these names need to be set in the HMI Application
and downloaded to the HMI.
Touch the Mode Button to select the mode of operation, these are explained on page 8.
Static
Cyclic
Intermittent Cycle
In Position
Intermittent In Position
Touch the Input Button to select if the sensor is Normally Open or Normally Closed.
Touch the Output Button to select the necessary response from the press control.
Bypass – Channel is not being used
Emergency Stop – Alarm will indicate, Press will stop immediately when fault occurs
Top Stop – Alarm will indicate, Press will stop at top when a fault occurs
Warning – Alarm will indicate, but press movement will not be impaired.
Touch Angle On/Off to enter values, the current setpoints are displayed to the right under Actual.
Touch Intermittent Interval window to select interval count if Intermittent Mode is selected.
Press Save Changes to save these settings to the current job.
Return to the Active Overview and Press “Save to Recipe” to save the changes permanently in the Job
Recipe.