Heat & Glo  •  CERONA-36-IFT, CERONA-42-IFT Installation Manual  •  2558-980 Rev. C  •  3/21

12 

12 

Reference Materials 

 

A.  Vent Components Diagrams

Figure 12.1 DVP Vent Components 

Pipe

Effective Length

Inches

Millimeters

DVP4

4

102

DVP6

6

152

DVP12

12

305

DVP24

24

610

DVP36

36

914

DVP48

48

1219

DVP6A

3 to 6

76 to 152

DVP12A

3 to 12 76 to 305

10-1/2 in.

(267 mm)

10-7/8 in.

(276 mm)

45°

7-3/8 in.

(187 mm)

11-3/8 in.

(289 mm)

1-1/4 in. (32 mm)

9-1/4 in.

(235 mm)

13-1/4 in.

(337 mm)

1/2 in.  TYP

DVP90ST (90° Elbow) 

10 in.

(254 mm)

10 in.

(254 mm)

1 in.

(25 mm)

DVP-FS (Ceiling Firestop)

DVP45 (45º Elbow)

DVP Pipe (see chart)

Effective

Height/Length

4-7/8 in.

(124 mm)

(13 mm)

10 in.

(254 mm)

1- 1/2 in.

(38 mm)

5 in.

(127 mm)

12 in.

(305 mm)

UP

DVP-HVS (Vent Support)

12 in.

(305 mm)

14 in.

(356 mm)

1 in.

(25 mm)

8 in.

(203 mm)

6 in.

(152 mm)

DVP-WS (Wall Shield Firestop)

Finished Height: 19-3/4 in./502 mm

UNIV-AS2 (Attic Insulation Shield)

Tab=1 in.

(25.4 mm)

20-3/4 in.

(527 mm)

14 IN.

(356 MM)

14 IN.

(356 MM)

20 IN.

(508 MM)

12 IN.

(305 MM)

DVP-RDS

ROOF DECK INSULATION SHIELD

Содержание CERONA-36-IFT

Страница 1: ...performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage...

Страница 2: ...Approved Pipe 16 B Vent Termination Minimum Clearances 16 C Vent Terminal Clearances 17 D Use of Elbows 18 E Adding Vent Components 19 F Install Support Brackets 20 G Vent Diagrams 20 5 Vent Clearanc...

Страница 3: ...nce for fuel type ___________________________ Was a conversion performed ___________________________ Leak check performed and inlet pressure verified ___________________________ Verified proper air sh...

Страница 4: ...placement glass MODELS CERONA 36 IFT CERONA 42 IFT LABORATORY Underwriters Laboratories Inc UL TYPE Direct Vent Heater STANDARD CSA ANSI Z21 88 2019 CSA 2 33 2019 C BTU Specifications E Non Combustibl...

Страница 5: ...ted gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or lo...

Страница 6: ...ormation consult a qualified service technician service agency or your dealer B Good Faith Wall Surface MEASUREMENTS FROM TOP EDGE OF THE OPENING 6 in 18 in 24 in 30 in 36 in TO CEILING 12 in APPLIANC...

Страница 7: ...rt of the control system and or gas control which has been under water Carefully remove the appliance and components from the packaging The vent system components and decorative barrier fronts may be...

Страница 8: ...nces refer to Sections 3 and 5 Inches Millimeter Inches Millimeter A 7 178 K 5 1 8 130 B 2 1 8 54 L 65 1 2 1664 C 43 1092 M 41 1 8 1046 D 23 1 2 597 N 21 3 4 551 E 30 1 4 767 O 28 1 2 724 F 33 7 8 860...

Страница 9: ...N 76 mm CERONA 36 IFT CERONA 42 IFT CERONA 36 IFT CERONA 42 IFT 34 1 4 IN 870 mm 28 11 16 IN 729 mm 1 1 8 IN 29 mm 34 1 8 IN 867 mm 37 1 2 IN 953 mm 2 13 16 IN 71 mm 1 1 8 IN 29 mm 30 7 8 IN 784 mm 38...

Страница 10: ...reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference Figure 3 3 Appliance Loca...

Страница 11: ...a header for horizon tal strength and utilizing Jack or Trimmer stud fastened to the King studs for vertical strength Note Refer to Section 10 for important information related to facing drywall speci...

Страница 12: ...IFT Inches 3 1 2 2 48 42 3 8 86 5 8 84 5 8 millimeters 89 51 1219 1076 2200 2150 Measurement for Trim Kit 3 1 2 in Additional Finishing Material Thickness Measurement without Trim Kit 2 in Additional...

Страница 13: ...311 222 1784 2134 457 CERONA 42 IFT Inches 12 1 4 8 3 4 74 3 8 88 1 8 18 millimeters 311 222 1889 2238 457 Framing Dimensions Passive Heat Side Discharge WARNING Risk of Fire DO NOT place combustible...

Страница 14: ...45 1 8 millimeters 51 1219 1146 CERONA 42 IFT Inches 2 48 52 1 8 millimeters 51 1219 1324 Mesh screen required for front discharge or open top discharge passive heat installations with discharge openi...

Страница 15: ...estops should be sealed with caulk with a minimum of 300 F continuous exposure rating to seal gaps Gas line holes and other openings should be sealed with caulk with a minimum of 300 F continu ous exp...

Страница 16: ...Technologies DVP venting systems Refer to Sec tion 12 A for vent component information and dimensions Only use listed decorative termination caps shrouds with Hearth Home Technologies approved venting...

Страница 17: ...arance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance termination mechanical or non mechanical 12 in 305 mm 12 in 305 mm I clearance to a mechanical...

Страница 18: ...ht pipe is allowed between two 45 elbows See Figure 4 5 Figure 4 6 shows the vertical and horizontal offsets for DVP elbows Figure 4 5 HORIZONTAL VERTICAL RUN RISE E F F E C T I V E L E N G T H Y X X...

Страница 19: ...f the distance is more than 4 inches the heat shield is NOT required If it is 4 inches or less the heat shield IS REQUIRED Install per the following steps See Figure 4 9 CORRECT INCORRECT 4 Fasten the...

Страница 20: ...ponent attach with a minimum of two 2 sheet metal screws Figure 4 11 SCREW 3 in 76 mm F Install Support Brackets Refer to Cinch Pipe and Termination Cap installation in structions General Rules SUBTRA...

Страница 21: ...re shown using the effective length of pipe See Section 12 A Figure 12 for information on effective length of pipe components Horizontal terminations are measured to the outside mounting surface flang...

Страница 22: ...7 0 m Maximum V1 H1 63 ft 19 2 m Maximum V1 Minimum H1 H2 Maximum 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 5 ft 1 5 m 3 ft 914 mm 8 ft 2 4 m 4 ft 1 2 m 11 ft 3 4 m 5 ft 1 5 m 14 ft 4 3 m 6 ft 1 8 m 17 ft 5...

Страница 23: ...t 914 mm 10 ft 3 0 m 4 ft 1 2 m 13 4 0 m 5 ft 1 5 m 16 4 9 m 6 ft 1 8 m 17 5 2 m 7 ft 2 1 m 22 6 7 m H1 H2 22 ft 6 7 m Max V1 V2 H1 H2 62 ft 18 9 m Max H2 H1 V2 V1 CAP V1 Figure 4 17 Note On vertical...

Страница 24: ...aximum Two Elbows H1 V2 V1 V1 Minimum H1 H2 Maximum 1 ft 305 mm 4 ft 1 2 m 2 ft 610 mm 7 ft 2 1 m 3 ft 914 mm 10 ft 3 0 m 4 ft 1 2 m 13 4 0 m 5 ft 1 5 m 16 4 9 m 6 ft 1 8 m 17 5 2 m 7 ft 2 1 m 22 6 7...

Страница 25: ...arance 1 in 25 mm clearance around vertical sections A B CERONA 36 IFT 66 1 2 65 1 2 1689 mm 1664 mm CERONA 42 IFT 71 70 1803 mm 1778 mm B Wall Penetration Framing Firestops Combustible Wall Penetrati...

Страница 26: ...top Floor Penetra tion Framing WARNING Risk of Fire DO NOT pack insu lation around the vent Maintain clearances to vent to prevent overheating A ceiling firestop MUST be used between floors and attics...

Страница 27: ...t with Sagging or loose insulation Insulation backing or plastic Framing and other combustible materials Block openings into the chase to prevent entry of blown in insulation Make sure insulation and...

Страница 28: ...screws in non shaded areas see Figure 6 3 APPLY FASTENERS FROM FASTENER PACKET IN SHADED AREAS WARNING WARNING Fire Risk Maintain specified clearances around the appliance DO NOT notch into the frami...

Страница 29: ...anagement system s that will be installed Locate the two heat management ports on the top of the appliance See Figure 6 6 Use a tin snips to remove one knockout for each heat management option being a...

Страница 30: ...es DO NOT penetrate inner pipe All outer pipe joints must be sealed using one of the meth ods below including the slip section that connects directly to the horizontal termination cap Apply a bead of...

Страница 31: ...pipe slip section elbow and cap outer flues shall be sealed B Assemble Slip Sections Slide the inner flue of the slip section into the inner flue of the pipe section and the outer flue of the slip se...

Страница 32: ...tions are aligned as shown in Figure 7 10 Pull carefully to separate the pieces of pipe Figure 7 10 Align and Disassemble Vent Sections Figure 7 9 Rotate Seams for Disassembly C Secure the Vent Sectio...

Страница 33: ...al edges are sharp Slide the storm collar onto the exposed pipe section and align brackets Insert a bolt provided through the brackets and install nut Do not completely tighten Slide the assembled sto...

Страница 34: ...mm minimum overlap of flue telescoping section is required Failure to maintain overlap could cause overheating and fire Vent termination must not be recessed in the wall Siding may be brought to the...

Страница 35: ...nce is occurring on the same circuit the use of surge protectors may help alleviate the interference Accessories Requirements This appliance may be used with a wall switch wall mounted thermostat and...

Страница 36: ...ent tab back slightly and tip the IFT ECM to disengage it from the pin and the shorter placement tab To reinstall the IFT ECM on the component tray engage the front place ment tab first The LED contro...

Страница 37: ...per operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched circuit Incorrect wiring will override IPI safety lockout Refer to Fig...

Страница 38: ...if line pressure is greater than 1 2 psig 9 9 Gas Information Gas Pressure Natural Gas Propane Minimum inlet pressure 5 0 in w c 11 0 in w c Maximum inlet pressure 10 0 in w c 13 0 in w c Manifold pre...

Страница 39: ...for different vent runs See Figure 9 1 Loosen the wing nut Push the air handle in to close the air shutter Pull the air handle out to open the air shutter Tighten the wing nut Shutter Setting Verific...

Страница 40: ...erials must never overhang into the glass opening Observe all clearances when applying combustible materials Seal gaps between the finished wall and appliance top and sides using a 300 F minimum seala...

Страница 41: ...g stud to framing stud Figure 10 3 Finishing Template Dimensions IMPORTANT INSTALLATION Note There are eight holes on the template pieces that are to be lined up with the holes in the non combustible...

Страница 42: ...d self tapping screws found in the manual bag to attach the template pieces Figure 10 7 Top and Arch Finishing Pieces Assembled 5 Install non combustible finishing material up to the edge of the templ...

Страница 43: ...ojections above the top front edge of the appliance Figure 10 12 Clearances to mantels or other combustibles above appliance Figure 10 13 Clearances to Mantel Legs or Wall Projections Acceptable on bo...

Страница 44: ...06 51 1562 CERONA 42 IFT in 44 3 4 16 3 4 16 2 61 1 2 mm 1137 425 406 51 1562 Figure 10 15 Clearances to mantels or other non combustibles above appliance NON COMBUSTIBLE FACING MATERIAL COMBUSTIBLE F...

Страница 45: ...n the Appliance Clean vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity WARNING Risk of Explosion Follow ember placement instructions in manual DO NOT...

Страница 46: ...bracket Move the right end of log 1 forward until it hits the stick on the burner The closer the log is to the burner the more glow you will get Don t place the log too close to the burner or sooting...

Страница 47: ...rner as shown See Figure 5 4 4 5 5 Figure 5 Figure 6 Figure 7 STEP 5 LOG 5 SRV2106 702 Place the right portion of log 5 on the formed area of log 1 Place the left side on the grate Set the notch of th...

Страница 48: ...ace log 1 over the back side of the burner plate and slide forward until log hits the grate Log cut out should fit over pilot bracket See Figure 2 2 2 Figure 3 FORM FITTED FORM FITTED TO GRATE TINE TO...

Страница 49: ...H FITS OVER FRONT GRATE BAR NOTCH FITS OVER FRONT GRATE BAR NOTCH FITS NOTCH FITS ON BURNER ON BURNER DETAIL DETAIL Figure 5 STEP 5 LOG 5 SRV2107 705 Place log 5 on the left side between the grate tin...

Страница 50: ...igure 11 4 Glass Assembly LATCHES BOTH BOTTOM AND TOP GLASS ASSEMBLY G Fixed Glass Assembly Removal and Re placement WARNING Risk of Asphyxiation Handle fixed glass assembly with care Inspect the gask...

Страница 51: ...3 8 in 289 mm 1 1 4 in 32 mm 9 1 4 in 235 mm 13 1 4 in 337 mm 1 2 in TYP DVP90ST 90 Elbow 10 in 254 mm 10 in 254 mm 1 in 25 mm DVP FS Ceiling Firestop DVP45 45 Elbow DVP Pipe see chart Effective Heigh...

Страница 52: ...to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is greater than 7 1 4 in 184...

Страница 53: ...1 4 in 337 mm RF12 Roof Flashing Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP...

Страница 54: ...mm 12 1 2 in 318 mm DVP TVHW VerticalTermination Cap Highwind 14 in 356 mm 12 in 305 mm 12 1 8 in 314 mm 7 1 8 in 181 mm 8 3 4 in 222 mm 1 5 8 in 41 mm 16 7 8 in 429 mm DVP HPC High Performance Cap 1...

Страница 55: ...gth 5 3 4 to 8 3 8 in 146 to 213 mm 5 1 2 in 140 mm 8 3 8 in 213 mm DVP HRC ZC SS Figure 12 5 DVP Vent Components DECORATIVE TERMINATIONS SHROUDS Only use listed decorative termination caps shrouds wi...

Страница 56: ...liance and are ordered separately from PVI SLP B Contact your dealer to order 16 IN 406 mm 15 IN 381 mm 16 11 16 IN 424 mm 9 3 16 IN 233 mm 4 1 2 IN 114 mm 16 11 16 IN 424 mm 13 5 8 IN 346 mm 12 1 2 I...

Страница 57: ...15 1 2 IN 394 mm 11 1 2 IN 292 mm 8 IN 203 mm 4 3 8 IN 112 mm 10 IN 254 mm 5 1 4 IN 135 mm 2 1 4 IN 57 mm 9 1 2 IN 241 mm 4 3 4 IN 121 mm 2 1 4 IN 57 mm 1 1 2 IN 38 mm 6 1 4 IN 159 mm Front View Top V...

Страница 58: ...s is required to power the PVV SLP and connect it to the appliance It is ordered separately from the PVV SLP Contact your dealer to order Note The PVV SLEEVE 12 and or PVV SLEEVE 48 is required to be...

Страница 59: ...er with any questions or concerns For the location of your nearest Heat Glo dealer please visit www heatnglo com Optional Heat Management Systems Kits After a qualified service technician has installe...

Отзывы: