Heat & Glo • CERONA-36-IFT, CERONA-42-IFT Installation Manual • 2558-980 Rev. C • 3/21
22
Top Vent - Horizontal Termination
H
1
V
1
Figure 4.15
Figure 4.16
One Elbow
Two Elbows
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
1
Minimum
H
1
Maximum
1 ft
305 mm
2 ft
610 mm
2 ft
610 mm
5 ft
1.5 m
3 ft
914 mm
8 ft
2.4 m
4 ft
1.2 m
11 ft
3.4 m
5 ft
1.5 m
14 ft
4.3 m
6 ft
1.8 m
17 ft
5.2 m
7 ft
2.1 m
20 ft
6.1 m
8 ft
2.4 m
23 ft
7.0 m
V
1
= 40 ft. (12.2 m) Maximum
H
1
= 23 ft. (7.0 m) Maximum
V
1
+ H
1
= 63 ft. (19.2 m) Maximum
V
1
Minimum
H
1
+ H
2
Maximum
1 ft
305 mm
2 ft
610 mm
2 ft
610 mm
5 ft
1.5 m
3 ft
914 mm
8 ft
2.4 m
4 ft
1.2 m
11 ft
3.4 m
5 ft
1.5 m
14 ft
4.3 m
6 ft
1.8 m
17 ft
5.2 m
7 ft
2.1 m
20 ft
6.1 m
8 ft
2.4 m
23 ft
7.0 m
V
1
+ H
1
+ H
2
= 63 ft. (19.2 m) Maximum
H
1
+ H
2
= 23 ft. (7.0 m) Maximum
Note:
Must have
a minimum verti
-
cal vent before
attaching a 90º
elbow to the
unit. See chart.
Minimal Vertical Vent
Model
ft. mm
CERONA-36-IFT
1
305
CERONA-42-IFT
1
305
Note:
Must have
a minimum verti
-
cal vent before
attaching a 90º
elbow to the
unit. See chart.
Minimal Vertical Vent
Model
ft. mm
CERONA-36-IFT
1
305
CERONA-42-IFT
1
305