37
Heat & Glo • CERONA-36-IFT, CERONA-42-IFT Installation Manual • 2558-980 Rev. C • 3/21
Figure 8.3 IntelliFire Touch Wiring Diagram
B. Wiring Requirements
IntelliFire Touch
®
Ignition System Wiring
NOTICE:
Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.3, IntelliFire Touch Wiring Diagram.
• This appliance is equipped with an IntelliFire Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
FLAME
SENSE IGNITER
TO JUNCTION
BOX 110-120 VAC
LED
CONTROL
RF MODULE
ORANGE
(PILOT)
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
RED
6V DC
BATTERY PACK
(OPTIONAL)
JUMPER
WIRE
APPLIANCE
ON/OFF
CONTROL BRN BLK
3 PRONG 110VAC
FAN
6 VAC
TRANSFORMER
BLK
IFT AUX MODULE
IFT CONTROL
MODULE
GREEN
(MAIN)
USB-C WIRE
ASSEMBLY
LIGHT TUB
ASSEMBLY
JUNCTION BOX
110-120 VAC
2326-013