Fitzroy Install NOV 2010 

www.yunca.co.nz 

Page 1 of 4 

A division of Terry Young Ltd , New Zealand 

INSTALLATION INSTRUCTIONS for 

FITZROY (Sub 1.0) FREESTANDING WOODBURNER 

NOVEMBER 2010 

 

TESTED in compliance with AS/NZS 2918: 2001 

 

A

. Yunca recommends that competent trades persons carry out all installations (e.g. NZHHA 

Registered Installer), to obtain maximum performance and safe, efficient heating. 

 

B

. A permit is required and we suggest you check with local building inspectors as by-laws do 

vary from area to area.  
Also notify your Insurance Company that a solid fuel heater has been installed.

 

 

C

. Floor Protector –  

1.  Must extend a minimum of 300mm in front of the door aperture. 
2.  Must extend at least 100mm from each side of the heater. 
3.  Ash Floor Protector must be constructed of non-combustible materials, with a 

minimum thickness of 12mm 

 

D

. Seismic restraint – Heater must be restrained from seismic movement as required by AS/NZS 

2918:2001. 10mm diameter bolting holes in the feet of the FITZROY allow restraint. 

 

E.

 Manufacturers’ recommended tested minimum clearances from combustible walls: 

 

Tested to AS/NZS 2918 : 2001 by APPLIED RESEARCH SERVICES 

Clearance 

Rear Clearance  – from rear of top lip 

(with YUNCA flue mounted shield fitted) 

                            - N.B. clearance from rear panel is 120mm 

100 mm 

 

Side Clearance (with YUNCA flue mounted shield fitted) 

300 mm 

Corner Clearance (with YUNCA flue mounted shield fitted) 

130 mm 

 

F. YUNCA Flue Kit (Tested to AS/NZS 2918:2001 Appendix F): Fig A, B & E

 

1

. 4.2m x 150mm stainless steel flue 

4

. 1 x insulation boundary shield. 

2

. 2.4m x 250mm galvanised liner. 

5. 

2 x spider brackets. 

3.

 1 x ceiling tile. 

6. 

1 x weather cap & cowl. 

 

Please Note: 

All flue joints must be sealed with flue sealing compound. Use stainless steel 

screws or rivets to join the flue pipe (three equally spaced places at each joint). The first 
length of flue pipe must be screwed to flue spigot. The required minimum flue termination 
height is 4.6 m above the floor protector. 

 

G. FITZROY Sub 1.0 Flue Mounted Shield (Flue Guard) Kit.  

Complies (with heater) to AS/NZS 2918:2001: Refer Fig A. 

1 x 1200mm length lined back guard plus an adjustable 900mm extension. 
1 x 1200mm length perforated front guard 
1 x 1200mm length tertiary back guard with spacer tabs. 
1 x Top front deflector shield (half round shape, angled 30 degrees when installed).  

Please Note: The minimum Flue Mounted Shield height Is 1200mm.  

 

Содержание fitzroy

Страница 1: ...walls Tested to AS NZS 2918 2001 by APPLIED RESEARCH SERVICES Clearance Rear Clearance from rear of top lip with YUNCA flue mounted shield fitted N B clearance from rear panel is 120mm 100 mm Side Clearance with YUNCA flue mounted shield fitted 300 mm Corner Clearance with YUNCA flue mounted shield fitted 130 mm F YUNCA Flue Kit Tested to AS NZS 2918 2001 Appendix F Fig A B E 1 4 2m x 150mm stainl...

Страница 2: ... FLUES Refer Fig E 1 The FLUE shall extend to Not less than 600mm above the highest point on the roof if within 3 0m of that point or Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3 0m In any case the length of the flue shall not be less than 4 6m from the ash floor protector In some situations the Local Council may vary the above r...

Страница 3: ...FLUE MOUNTED SHIELD FITTED Measurements in millimetres A B E F G H 100 300 130 320 620 501 FIG D MINIMUM FLOOR PROTECTION MEASUREMENTS WITH YUNCA FLUE MOUNTED SHIELD FITTED Measurements in millimetres C D J K L M N O P 300 100 840 880 1274 1150 560 640 580 Above Non combustible wall clearances Brick lining from floor to within 25mm of ceiling Leave air vents at the bottom to allow airflow in the c...

Страница 4: ...THE MARKING TESTED TO AS NZS 4013 C ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 D MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION ...