C. Facing and Finishing - Radius Decorative
Front (4 Inch Maximum Non-Combustible)
DO NOT BLOCK CONVECTION VENTS
WALL
SHEET ROCK
NON-COMBUSTIBLE
FINISH MATERIAL
4 IN. THICK MAX.
RADIUS DOOR
Figure 10.10 Radius Door
4 IN. MAX.
(MEASURED FROM
SHEET ROCK)
DOOR FLUSH TO
SHEET ROCK
NON-COMBUSTIBLE
MATERIAL
4 IN. THICK MAX.
WALL
SHEET ROCK
RADIUS DOOR
*GAP =1/2 IN.
*The gap around the decorative front is needed for removing
and installing the Radius decorative front.
Figure 10.11 Radius Door
*1/2 IN.
*1/2 IN.
NON-COMBUSTIBLE
FINISH MATERIAL
CLEARANCE TO
RADIUS DOOR
*1/2 IN.
*1/2 IN.
*The gap around the decorative front is needed for removing
and installing the Radius decorative front.
Figure 10.12 Radius Door - Clearance to Non-Combustible
Finishing Material
REMOVE CLIPS
FINISHING STRIP
Remove and discard finishing strip before installation of
appliance. See Figure 10.4. The finishing strip is not be
used with the Radius decorative front.
Figure 10.9 Remove Finishing Strip (Not used with Radius
Decorative Front)