Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
48
DO NOT BLOCK CONVECTION VENTS
Figure 10.5 Radius Door
B. Facing and Finishing - Radius Decorative
Front (1 Inch Max. Non-Combustible)
SHEET ROCK
FINISHING MATERIAL
NON-COMBUSTIBLE
1 IN. THICK MAX.
WALL
ZERO CLEARANCE
(TO APPLIANCE OUTER WRAP)
ALL 4 SIDES
NOTE: The Radius
front will rest an
additional 1 inch from
the appliance when
finishing up to the
appliance outer wrap.
APPLIANCE OUTER WRAP
RADIUS
DOOR
Figure 10.6 Radius Door - Side View
WALL
SHEET ROCK
NON-COMBUSTIBLE
FINISH MATERIAL
1 IN. THICK MAX.
OUTER WRAP
RADIUS DOOR
Figure 10.7 Radius Door - Non-Combustible Facing Diagram
The following instructions apply to facing and finishing
materials up to one inch thick, made of non-combustible
material, finished up to the appliance outer wrap and
used with the Radius decorative front. For the definition
of non-combustible materials, see Section 1.E.
Remove and discard finishing strip before installation of
appliance. See Figure 10.4. The finishing strip is not be
used with the Radius decorative front.
REMOVE CLIPS
FINISHING STRIP
Figure 10.4 Remove Finishing Strip (Not used with Radius
Decorative Front)