Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
56
Figure 11.3. In-Wall Tub Installation
INSTALL HERE
TUB ASSEMBLY
INSTALLED
FIRESTOP/
OUTER WRAP
INSTALLED
NON-COMBUSTIBLE
BOARD INSTALLED
(6 SCREWS)
CUT THROUGH
INSULATION
& WALL
NON-COMBUSTIBLE
BOARD
FINISHED
FLOOR
INSULATION
INSTALLED
APPLIANCE
INSTALLED
OUTER WRAP
INSTALLED
HOLES FOR
ATTACHING
OUTER WRAP
4 IN. TO
FINISHED
FLOOR
TUB ASSEMBLY
INSTALLED
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE
BOARD
CORRUGATED
TEMPLATE
GAS
ACCESS
ELECTRICAL
ACCESS
NOTE: REMOVE CORRUGATED TEMPLATE
BEFORE INSTALLING INSULATION
FINISHED
FLOOR
A
B
C
D
E
F
G
H
I
SCREWS
SCREWS
SCREWS
NOTE: INSTALL
SCREWS
REMOVE TOP FINISHING STRIP FROM APPLIANCE BEFORE INSTALLING IN TUB.
SEE FIGURE 11.9.