Napoleon Ascent Linear Series Скачать руководство пользователя страница 1

FRENCH PG. 65

W415-2757 / B / 01.09.20

BL36PTE-1 / BL46PTE

ADD MANUAL TITLE 

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone 1 (866) 820-8686 • www.napoleon.com • [email protected]

CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS: 

CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES

INSTALLER: 

Leave this manual with the appliance

CONSUMER: 

Retain this manual for future reference

ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)

NATURAL GAS MODELS:

PROPANE GAS MODELS:

Product Name / Code

(MUST use title from Price Book)

ADD ____ ILLUSTRATED

ADD PRODUCT IMAGE

CSA / 

INTERTEK

LOGO

SAFETY INFORMATION

- Do not store or use gasoline or other 
fl ammable vapors and liquids in the vicinity of 
this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

:

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not 
use any phone in your building.

• 

Immediately call your gas supplier from a 
neighbour’s phone. Follow the gas    
supplier’s  instructions.

• 

If you cannot reach your gas supplier, call 
the fi re department.

- Installation and service must be 
performed by a qualifi ed installer, service 
agency, or the supplier.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is only for use with the type of gas  
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless 
a certifi ed kit is used. 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage.

WARNING

!

ENGLISH 

$10.00

FOR INDOOR USE ONLY

IF INSTAL OPERATION, ADD SERIAL 

NUMBER LABEL HERE

IF SEPARATE MANUALS, ADD “PLACE 

BARCODE LABEL ON THE OWNER’S MANUAL”

SAFETY BARRIER

Ascent™ Linear Series

(BL46 illustrated)

INSTALLATION MANUAL 

BL36NTE-1 / BL46NTE

PLACE BARCODE LABEL ON THE 

OWNER’S MANUAL

Содержание Ascent Linear Series

Страница 1: ...electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call t...

Страница 2: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and...

Страница 3: ...anemia those under the in uence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in sooti...

Страница 4: ...ng vertical vents 32 5 6 vertical through existing chimney 33 6 0 electrical information 34 6 1 hard wiring connection 34 6 2 receptacle wiring diagram 34 6 3 electronic wiring diagram 34 6 4 optional...

Страница 5: ...yer or similar heat source This appliance is a decorative product It is not a source of heat and not intended to burn solid fuel note Batteries must be disposed of according to the local laws and regu...

Страница 6: ...ier installed and secure Are all required accessories installed i e door trims Venting Installation Is the venting configuration within the parameters Has the venting been sealed with the appropriate...

Страница 7: ...3 Place the appliance in its nal position 4 Install nailing tabs refer to nailing tab installation section 5 Install appliance venting refer to venting installation section 6 Install all electrical w...

Страница 8: ...ed combustion product The installation must conform with local codes or in absence of local codes the National Gas and Propane Installation Code CSA B149 1 in Canada or the National Fuel Gas Code ANSI...

Страница 9: ...uation Il est n cessaire de bien r installer et resceller l vacuation apr s avoir executer l entretien du syst me de prise d air Serial Number N de S rie W385 XXXX REFERENCE 161746 XXXX VENTED DECORAT...

Страница 10: ...re list Ref Description Quantity BL36 1 BL46 1 Self drilling screw 6 6 2 Sheet metal screw 18 18 3 Sheet metal screw 4 4 4 Quad drive sheet metal screw 4 4 5 Sheet metal screw 4 4 2 3 4 5 1 Only faste...

Страница 11: ...BL36 1 Finishing flange depth the finishing flange defines the perimeter of the fireplace opening framing or finishing materials must NEVER encroach inside the finishing flange PP PP PP PP PP PP PP P...

Страница 12: ...th the finishing flange defines the perimeter of the fireplace opening framing or finishing materials must NEVER encroach inside the finishing flange ng flange defines the perimeter of the PP PP PP PP...

Страница 13: ...e vent length and number of elbows to a minimum The air terminal must remain unobstructed at all times Examine the air terminal at least once a year to verify that it is unobstructed and undamaged Rig...

Страница 14: ...r foot or 21mm rise per meter using exible venting For safe and proper operation of the appliance follow the venting instructions exactly A terminal shall not terminate directly above a sidewalk or pa...

Страница 15: ...ination 33 1 8 84 1cm Use the periscope kit to locate the air termination above grade The periscope must be installed so that when nal grading is completed the bottom air slot is located a minimum 12...

Страница 16: ...h deck or overhang N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without...

Страница 17: ...qual to or greater than the horizontal run Horizontal run vertical rise to maximum of 40 feet 12 2m Horizontal run vertical rise to maximum of 40 feet 12 2m Vertical Termination For the following symb...

Страница 18: ...12 2m Example V1 3 ft 0 9m V2 8 ft 2 4m VT V1 V2 3 ft 0 9m 8 ft 2 4m 11 ft 3 4m H1 2 5 ft 0 8m H2 2 ft 0 6m HR H1 H2 2 5ft 0 8m 2 ft 0 6m 4 5 ft 1 4m HO 03 two 90 elbows 90 03 180 90 5 4 ft 1 7m HT H...

Страница 19: ...75 FT 7 5m Since both formulas are met this vent configuration is acceptable The shaded area within the lines represents acceptable values for HT and VT 90 V1 H1 H2 90 Example V1 4 FT 1 2m V2 1 5 FT 0...

Страница 20: ...8m HR H1 H2 8 ft 2 4m 2 5 ft 0 8m 10 5 ft 3 2m HO 03 four 90 elbows 90 03 360 90 8 1 ft 2 5m HT HR HO 10 5 ft 3 2m 8 1 ft 2 5m 18 6 ft 5 7m HT VT 18 6 ft 5 7m 21 ft 6 4m 39 6 ft 12 1m Formula 1 HT VT...

Страница 21: ...HR HO 8 ft 2 4m 8 1 ft 2 5m 16 1 ft 4 9m HT VT 16 1ft 4 9m 4 5 ft 1 4m 20 6 ft 6 3m Formula 1 HT 3VT 3VT 3 ft 0 9m x 4 5 ft 1 4m 13 5 ft 4 1m 16 1 ft 4 9m 13 5 ft 4 1m Since this formula is not met th...

Страница 22: ...8 vent shield installation BL46 only A Form vent shield to a 90 angle as illustrated in installation step above B Install the vent shield by securing it to top of appliance using 2 screws supplied C A...

Страница 23: ...s Materials consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof are suitable Materials that are reported as passing ASTM E136 standard test method...

Страница 24: ...cm vertical vent rise made immediately off the appliance collar note 4 1 minimum framing dimensions Do not put objects in front of the appliance minimum distance of 4 feet BL36 1 BL46 A 16 40 6cm 18 9...

Страница 25: ...Before framing your appliance determine vent requirements before deciding the nal location of the appliance After rough framing place the appliance in its nal position A B BL36 1 BL46 A 16 40 6cm 18 9...

Страница 26: ...minimum of 3 screws must also be used to ensure the connection cannot slip off Do not clamp the exible vent pipe Risk of re explosion or asphyxiation Improper support of the entire venting system may...

Страница 27: ...roof Installation kits for various roof pitches are available from your authorized dealer distributor See the accessories section to order speci c kits required A Determine the air terminal location c...

Страница 28: ...ts return ange ADD FASTENER TYPE ADD GRAPHIC For safe and proper operation of the appliance follow the venting instructions exactly The vent system must be supported approximately every 3 feet 0 9m fo...

Страница 29: ...rough the roof The air terminal must be positioned vertically and plumb Attach the air terminal connector to the roof support ensuring that the top of the air terminal is 16 40 6cm above the highest p...

Страница 30: ...screws Repeat using the outer rigid pipe Seal using Red RTV Silicone W573 0002 not supplied C Insert the vent pipes through the restop maintaining the required clearance to combustibles Apply a heavy...

Страница 31: ...minal connector Place the ashing over the air terminal connector and slide it underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centered within the...

Страница 32: ...l approved restrictor kit This kit is not recommended for short vertical vent runs Depending on the model and or year of your appliance mounting holes may not exist A If mounting holes exist remove th...

Страница 33: ...air intake ex liner and the exhaust collar must be connected to the exhaust exible liner Both Simpson Duravent and Selkirk co linear to co axial adaptors have been approved on this appliance Follow v...

Страница 34: ...e recommended maximum lead length depends on wire size WIRE SIZE MAX LENGTH 14 gauge 1 8mm 100 feet 30 5m 16 gauge 1 5mm 60 feet 18 3m 18 gauge 1 2mm 40 feet 12 2m Disconnect the existing wires from t...

Страница 35: ...move the safety barrier to easily access the control compartment E Attach the wire on connector labelled BATTERY from the wiring harness located in the control compartment of the appliance to the batt...

Страница 36: ...OUND STAR MAIN LINE W190 0113 CONTROL MODULE Do not wire 110 volts to the valve or wall switch WARNING This appliance comes equipped with a battery back up If this back up is used install 4 AA batteri...

Страница 37: ...have been factory set do not change Installation and servicing to be done by a quali ed installer Move the appliance into position and secure If equipped with a ex connector the appliance is designed...

Страница 38: ...switch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your service technician or gas supplier A Set thermostat to lowest setting if equipped B Turn o...

Страница 39: ...ner is turned off A timer will then begin the countdown for approximately seven days before shutting off the pilot if the appliance is not used This countdown will reset anytime the appliance main bur...

Страница 40: ...into this area it must be left clear to provide adequate clearance for the vent in this 14 35 6cm wide area centered along the front of the appliance The appliance should be in its nal location before...

Страница 41: ...1 2 92 7cm 47 3 8 120 3cm H 56 142 2cm J 4 10 2cm DRYWALL CEILING J H B I A maximum Do not build into this area it must be left clear to provide adequate clearance for the vent in this 14 35 6cm wide...

Страница 42: ...aterial Non combustible material Combustible Non combustible 56 142 2cm ceiling min 27 1 2 69 9cm 1 25 4mm 46 116 8cm 6 1 2 16 5cm 3 76 2mm top 1 25 4mm bottom 14 35 6cm Vent shield Top of combustible...

Страница 43: ...are maintained The minimum enclosure volume must be increased by no less than the volume of the recess This adjustment can be made by increasing any or all of the height width and depth of the enclos...

Страница 44: ...appliance with glass removed cracked or scratched Facing and or nishing material must never overhang into the appliance opening The glass door assembly is designed to pivot forward when relieving exc...

Страница 45: ...ppliance for maintenance WARNING DOOR WITH SAFETY BARRIER 4 101 6mm 6 152 4mm 2 50 8mm 0 0mm 5 127mm 3 76 2mm APPLIANCE OPENING L BL36 1 31 9 16 80 2cm BL46 42 1 2 107 9cm Joint Compound where require...

Страница 46: ...2 50 8mm 4 101 6mm 6 152 4mm 8 203 2mm MANTEL 27 1 2 69 9cm 39 1 2 100 3cm 12 30 5cm 6 152 4mm 4 101 6mm 2 50 8mm 2 3 9 1 9 12 30 5cm 2 4 6 8 10 12 MANTEL DEPTH INCHES 14 35 6cm 16 40 6cm 20 50 8cm 2...

Страница 47: ...Before the glass door can be removed the safety barrier must be removed Lift the safety barrier off the four shoulder screws and remove from the appliance Leave a hand on the glass door during entire...

Страница 48: ...re with the pilot operation Evenly spread the glass media onto the media tray covering the burner tube and tray Ensure no glass media falls into the pilot opening If this happens insert a clean bag in...

Страница 49: ...ppliance B Remove the door from the appliance by releasing the door latches C It may be necessary to move the control module aside during blower installation D Attach the two 1 4 connectors black and...

Страница 50: ...may display a very active ame If this appearance is not desirable the vent exit must be restricted using a restrictor vent kit Refer to the replacement parts section of the owner s manual for the appr...

Страница 51: ...ed on the chart below Check pressure with main burner operating on HI After taking pressure readings be sure to turn screws clockwise rmly to reseal Do not overtorque Leak test with a soap and water s...

Страница 52: ...gnition takes longer consult your local authorized dealer dis tributor 9 Visually inspect the appliance for carbon build up Using a small whisk or brush brush off the carbon and vacuum up or sweep int...

Страница 53: ...aps on the rebox top Ensure they open freely and close sealed Check the gas control valve pilot and Hi Lo knobs move freely if equipped Replace if any stiffness in movement is experienced Check for g...

Страница 54: ...warranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of applia...

Страница 55: ...trol cover Yes W570 0192 Shoulder screw x2 For replacement parts refer to valve train assembly W010 3631 SER Door assembly W562 0009 Door gasket kit Yes W300 0231 Topaz glass media Yes W010 3554 Door...

Страница 56: ...er ori ce 48 NG Yes 13 W456 0056 Burner ori ce 56 P Yes 14 15 16 16 Yes 17 Yes Yes Yes 18 W335 0039 Pilot hood W455 0070 Pilot ori ce 62 NG W455 0068 Pilot ori ce 35 P W720 0062 Pilot tube w ttings W2...

Страница 57: ...Control cover Yes W570 0192 Shoulder screw For replacement parts refer to valve train assembly W010 4100 SER Door assembly W562 0060 Door gasket kit Yes W300 0135 Topaz glass media Yes W385 2010 Napo...

Страница 58: ...e 43 NG Yes 13 W456 0053 Burner Orifice 53 P Yes 14 15 16 16 Yes 17 Yes Yes Yes 18 W335 0039 Pilot hood W455 0070 Pilot orifice 62 NG W455 0068 Pilot orifice 35 P W720 0062 Pilot tube w fittings W240...

Страница 59: ...Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustments section in the installation manual Carbon is being deposited on...

Страница 60: ...eiver if equipped Reset program hold reset button on receiver and wait for 2 beeps Release after second beep Press small ame button on remote within 20 seconds you will hear an additional beep this si...

Страница 61: ...e one of the 3 methods below to reset the system 1 To reset ignition box when locked out Turn off power supply and remove batteries if used from the back up battery pack 2 To reset the DFC Board when...

Страница 62: ...t be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to the appliance combustion chamber heat exchanger plated trim or other components due to water weather d...

Страница 63: ...B 01 09 20 63 service history 16 0 service history Appliance Service History This appliance must be serviced annually depending on usage Date Dealer Name Service Technician Name Service Performed Spec...

Страница 64: ...TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadienne...

Страница 65: ...retien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquement avec le...

Страница 66: ...aux br lures accidentelles Une barri re de protection est recommand e si des individus risque se trouvent dans la maison A n de restreindre l acc s l appareil installez une barri re de protection ajus...

Страница 67: ...peut entra ner la formation de suies et dommages la propri t Comme dans le cas de tout appareil combustion il est recommand de faire inspecter et entretenir votre appareil r guli rement De m me insta...

Страница 68: ...es vents verticaux 96 5 6 terminaison verticale travers une chemin e existante 97 6 0 sch ma de c blage 98 6 1 branchement par c ble 98 6 2 sch ma de c blage du r ceptacle 98 6 3 sch ma de c blage lec...

Страница 69: ...e de chaleur similaire Cet appareil est une produit d corative Cet appareil n est pas une source de chaleur et un combustible solide ne doit pas tre utilis avec cet appareil note Les piles doivent tre...

Страница 70: ...llation du syst me d vents La configuration du syst me d vents est elle conforme aux param tres Le syst me d vents a t il t scell avec le scellant appropri Le syst me d vents est il support et fix en...

Страница 71: ...cadrement approximatif 3 Placer l appareil dans le position nale 4 Installer les pattes du cloutage r f rez la section installation des pattes du cloutage 5 Installer l vacuation de l appareil r f rez...

Страница 72: ...914 4mm Un d tecteur de monoxyde de carbone est requis dans toutes les pi ces contenant des appareils aliment s au gaz L appareil n est pas approuv pour installation dans une chambre coucher ou une s...

Страница 73: ...de S rie W385 XXXX REFERENCE 161746 XXXX VENTED DECORATIVE GAS APPLIANCE NOT A SOURCE OF HEAT NOT INTENDED FOR USE AS A HEATING APPLIANCE NOT FOR USE WITH SOLID FUEL APPAREIL GAZ D CORATIF VACUATION...

Страница 74: ...ription Quantit BL36 1 BL46 1 Vis auto perforante 6 6 2 Vis de feuille m tallique 18 18 3 Vis de feuille m tallique 4 4 4 Vis de feuille m tallique t te bomb e 4 4 5 Vis de feuille m tallique 4 4 2 3...

Страница 75: ...23 9 2 0 dimensions 2 1 BL36 1 VUE AVANT VUE DU C T DROITE VUE DE DESSUS La profondeur de la bride definition la bride de finition d finit le p rim tre de l ouverture de la chemin e les mat riaux de c...

Страница 76: ...5 7 6 9 723 9 2 2 BL46 VUE AVANT VUE DU C T DROITE VUE DE DESSUS La profondeur de la bride definition la bride de finition d finit le p rim tre de l ouverture de la chemin e les mat riaux de charpente...

Страница 77: ...exception du raccordement du conduit d vacuation la buse du foyer qui doit tre scell avec le scellant noir haute temp rature Mill Pac Le scellant haute temp rature doit tre command s par ment Syst me...

Страница 78: ...exibles le nombre maximal de raccordements est de deux horizontalement ou trois verticalement excluant les raccordements l appareil et la section de terminaison Les courses horizontales peut avoir un...

Страница 79: ...m Utilisez l ensemble p riscopique a n de positionner la terminaison au dessus du niveau du sol L ensemble p riscopique doit tre install de fa on ce que la fente d air du bas soit situ e un minimum de...

Страница 80: ...ement des murs adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8...

Страница 81: ...ticale jusqu un maximum de 40 12 2m La course horizontale la course verticale jusqu un maximum de 40 12 2m Terminaison verticale Les symboles suivants sont utilis s dans le calcul et les exemples d va...

Страница 82: ...mule 2 HT VT 40 pieds 12 2m Exemple V1 3 pi 0 9m V2 8 pi 2 4m VT V1 V2 3 pi 0 9m 8 pi 2 4m 11 pi 3 4m H1 2 5 pi 0 8m H2 2 pi 0 6m HR H1 H2 2 5 pi 0 8m 2 pi 0 6m 4 5 pi 1 4m HO 0 03 deux 90 elbows 90 0...

Страница 83: ...PI 5 1m Formule 1 HT 4 2 VT 4 2 VT 4 2PI 1 3m x 6PI 1 8m 25 2 PI 7 7m Formule 2 HT VT 24 75 PI 7 5m 16 7PI 5 1m 24 75 PI 7 5m Puisque les deux formules sont respect es cette configuration d vacuation...

Страница 84: ...2 4m 2 5 pi 0 8m 10 5 pi 3 2m HO 0 03 four 90 elbows 90 0 03 360 90 8 1 pi 2 5m HT HR HO 10 5 pi 3 2m 8 1 pi 2 5m 18 6 pi 5 7m HT VT 18 6 pi 5 7m 21 pi 6 4m 39 6 pi 12 1m Formule 1 HT VT 18 6 pi 5 7m...

Страница 85: ...iquent Formule 1 HT 3VT Formule 2 HT VT 40 pieds 12 2m Exemple V1 2 PI 0 6m V2 1 PI 0 3m V3 1 5 PI 0 5m VT V1 V2 V3 2PI 0 6m 1PI 0 3m 1 5PI 0 5m 4 5 PI 1 4m H1 6 PI 1 8m H2 2 PI 0 6m HR H1 H2 6PI 1 8m...

Страница 86: ...l cran protecteur BL46 seulement A Bouclier de vent forme un angle de 90 comme illustr l tape d installation ci dessus B Installez le pare vent en le xant en haut de l appareil l aide de 2 vis fourni...

Страница 87: ...at riaux r pondant la norme ASTM E 136 m thode de test standard du comportement des mat riaux dans une fournaise avec tube vertical 1382 F 750 C et la norme UL763 sont consid r s comme tant des mat ri...

Страница 88: ...ment au collet de l appareil note 4 1 dimensions minimaux de l encadrement Do not put objects in front of the appliance minimum distance of 4 feet BL36 1 BL46 A 16 40 6cm 18 9 16 47 1cm B 36 1 2 92 7c...

Страница 89: ...encadrer votre appareil d terminez les exigences d vacuation avant de d cider de l emplacement nal de l appareil Apr s l ossature approximatif placez l appareil dans sa position nale A B BL36 1 BL46 A...

Страница 90: ...staller trois vis pour vous assurer que le raccordement ne d fasse pas Ne serrez pas la gaine exible Risque d incendie d explosion ou d asphyxie Si l ensemble du syst me de conduit d vent n est pas ad...

Страница 91: ...feu Calfeutrage Protecteur du conduit d vacuation Protecteur du conduit d vacuation Collet de conduit d vacuation Espaceur coupe feu face inf rieure des solves 10 3 4 273mm 10 3 4 273mm 5 1 installati...

Страница 92: ...e de composants d vacuation rigide suivez les instructions d installation et des exigences de scellage du fabricant A tirez la gaine exible int rieure la longueur requise en tenant compte de la longue...

Страница 93: ...ux Assurez vous que le connecteur de terminaison est bien centr dans le solin en laissant une marge de 3 4 19 1mm tout autour Fixez le au toit Ne clouez pas travers la partie inf rieure du solin Imper...

Страница 94: ...s tant l endroit et lisibles xez la au mur ext rieur et rendez la tanche en la scellant avec du calfeutrage non fourni La plaque de montage de la terminaison peut tre ench ss e dans le mur ou le rev t...

Страница 95: ...le solin par dessus le connecteur de terminaison et glissez le sous les c t s et le bord sup rieur des bardeaux Assurez vous que le connecteur de terminaison est bien centr dans le solin en laissant...

Страница 96: ...teel approuv Ce kit n est pas recommand pour les longueurs de conduit d vacuation vertical court Selon le mod le et ann e de votre appareil les trous de xation peut ne pas exister A Si les trous de xa...

Страница 97: ...doit tre raccord au conduit exible de prise d air et le collet d vacuation de la terminaison au conduit exible d vacuation Les adaptateurs colin aire coaxial Simpson Duravent et Selkirk sont approuv s...

Страница 98: ...calibre du l DIAM TRE DU FIL LONGUEUR MAX Calibre 14 1 8mm 100 pieds 30 5m Calibre 16 1 5mm 60 pieds 18 3m Calibre 18 1 2mm 40 pieds 12 2m D brancher les ls existants des terminaux 1 et 3 partir de l...

Страница 99: ...rotection pour acc der le compartment de contr les E Brancher la l BATTERY pile du harnais de ls il se trouve au compartment de contr le de l appareil au sauvegarde de pile F Placer le sauvegarde de p...

Страница 100: ...de de pile a t fourni pour appareil mais non connect En cas d une panne de courrant installez quatre piles AA dans le sauvegarde de pile et attachez le l harnais de ls comme illustr e Connectez le sau...

Страница 101: ...que les pressions d essai exc dent 1 2 LB PO2 3 5 KPA Les r glages de la soupape ont t faits en usine ne les modi ez pas L installation et l entretien doivent tre effectu es par un installateur quali...

Страница 102: ...s de couper l alimentation de gaz et puis appelez votre technicien de service ou fournisseur de gaz A R gler le thermostat la r glage le plus bas si quip B Tournez l interrupteur murale de l appareil...

Страница 103: ...use si l appareil n est pas utilis Ce d compte se r initialisera chaque fois que le br leur principal de l appareil sera allum Par cons quent si l appareil est utilis r guli rement sur une base journa...

Страница 104: ...geur centr le long de l avant de l appareil Cet espace doit rest libre a n d offrir un d gagement ad quat pour l vacuation Aucun mat riaux combustible n est permis AVERTISSEMENT BL36 1 BL46 B 36 1 2 9...

Страница 105: ...47 3 8 120 3cm H 56 142 2cm J 4 10 2cm DRYWALL CEILING J H B I A maximum Ne construisez pas dans cet espace de 14 35 6cm de largeur centr le long de l avant de l appareil Cet espace doit rest libre a...

Страница 106: ...6cm Vent shield Top of combustible opening Center of vent pipe 3 76 2mm minimum all sides for vertical venting 3 76 2mm L cran protecteur est t l scopique et doivent tre ajust protection toute la pro...

Страница 107: ...ceinte doit tre augment d au moins la valeur du volume de la zone encastr e Cet ajustement peut tre r alis en augmentant une ou toutes les dimensions de l enceinte APPAREIL ZONE ENCASTR E OU ALC VE ZO...

Страница 108: ...e est enlev e ssur e bris e ou gratign e Les mat riaux de fa ade ou de nition ne doivent jamais empi ter sur l ouverture de l appareil L assemblage de la porte en verre est con u pour pivoter vers l a...

Страница 109: ...AVERTISSEMENT DOOR WITH SAFETY BARRIER 4 101 6mm 6 152 4mm 2 50 8mm 0 0mm 5 127mm 3 76 2mm FIREPLACE OPENING L BL36 1 31 9 16 80 2cm BL46 42 1 2 107 9cm Compos joints au besoin D lib rations et nouvea...

Страница 110: ...203 2mm MANTEL 27 1 2 69 9cm 39 1 2 100 3cm 12 30 5cm 6 152 4mm 4 101 6mm 2 50 8mm 2 3 9 1 9 12 30 5cm 2 4 6 8 10 12 MANTEL DEPTH INCHES 14 35 6cm 16 40 6cm 20 50 8cm 22 55 8cm 18 45 7cm Installation...

Страница 111: ...tre chaude est condition que avec l appareil sera tre install s Avant d enlever la porte vitr e l cran de protection doit tre enlever Soulevez l cran de protection hors des 4 goupilles et enlever de l...

Страница 112: ...rait avec l op ration de la pilote parpillez soigneusement les braises vitri es sur le plateau de mani re uniforme Assurez vous qu aucun morceau de verre ne tombe dans le zone de la veilleuse Si cela...

Страница 113: ...protection et enlevez le de l appareil B Enlevez la porte de l appareil en d gageant les loquets C Il peut tre n cessaire de d branchez le module de contr le et soulevez le du bas de l appareil pour l...

Страница 114: ...ir une amme tr s active Si cette apparence n est pas d sir e la sortie du conduit d vacuation doit tre r duite en utilisant une plaque de restriction Pour obtenir l ensemble appropri voir la section p...

Страница 115: ...V ri er la pression avec le br leur principale sur HI Apr s avoir pris la lecture des pressions assurez vous de tourner fermement les vis vers la droite pour sceller Ne serrez pas trop fort V ri ez p...

Страница 116: ...e bouton de contr le du gaz est ON Un temps d allumage total de 5 10 secondes est satisfaisant Si l allumage prend plus de temps consultez votre revendeur agr ou du distributeur 9 Inspectez visuelleme...

Страница 117: ...de la porte est ssur remplacer Seulement utiliser le verre fourni par votre d taillant autoris V ri ez si la soupape de gaz de la veilleuse et les boutons Hi Lo bougent librement s il y a lieu rem pl...

Страница 118: ...cement de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsque vous commandez des pi ces donnez toujours l information suivante Mod le et n...

Страница 119: ...192 Vis paulement Pour les pi ces de remplacement voir l assemblage de la soupape W010 3631 SER L assemblage de la porte W562 0009 Joint d tanch it de la porte Oui W300 0231 Braises vitrifi es topaze...

Страница 120: ...eur de veilleuse 56 P Oui 14 15 16 16 Oui 17 Oui Oui Oui 18 W335 0039 Hotte de veilleuse W455 0070 Injecteur de veuilleuse 62 GN W455 0068 W720 0062 Tube de veilleuse raccord W240 0013 Allumeur avec f...

Страница 121: ...192 Vis paulement Pour les pi ces de remplacement voir l assemblage de la soupape W010 4100 SER L assemblage de la porte W562 0060 Joint d tanch it de la porte Oui W300 0135 Braises vitrifi es topaze...

Страница 122: ...eur de veilleuse 53 P Oui 14 15 16 16 Oui 17 Oui Oui Oui 18 W335 0039 Hotte de veilleuse W455 0070 Injecteur de veilleuse 62 GN W455 0068 Injecteur de veilleuse 35 P W720 0062 Tube de veilleuse raccor...

Страница 123: ...d eau savonneuse Le volet d air est r gl incorrectement Voir la section r glage du venturi pour le r glage de l ouverture du volet d air dans le manual d installation Du carbone se d pose sur la vitr...

Страница 124: ...ion de la veilleuse Le module n est pas mis la terre Assurez le bon polarit du thermocouple si fourni V ri ez si les assemblages de le veilleuse et de la soupape sont bien mis la terre R cepteur si qu...

Страница 125: ...sur la che vers le haut la s quence d allumage se d clenchera En position off appuyez sur le bouton on de la t l commande Environ 4 secondes apr s que le bouton on off ait t enfonc le tableau d alluma...

Страница 126: ...dit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de Napol on Durant les dix premi res ann es Napol on remplacera ou r parera les pi ces d fec...

Страница 127: ...20 127 garantie FR Historique de service de l appareil Cet appareil doit tre entretenu annuellement selon son usage Date D taillant Nom du Technicien Travail Effectu Probl mes Particuliers 16 0 histo...

Страница 128: ...US S D DE E 4 40 0 A AN NS S D D E EXISTENCE C C C C C CO O O O O ON N N N N N N N NS S S S S SA A A A A AC C C CR R R R R S S L L LA A C CO ON NC CE EP PT TIO ON N D DE PR RODUITS DE CONFORT 7200 Rou...

Отзывы: