7 Commissioning the HDG Euro – Commissioning the HDG Euro
74
HDG Euro V3.0 with HDG Lambda Control 1 - V 1 - en
©
HDG Bavaria GmbH 06/2008
Grate lifter
The position of the grate lifter (2) can be changed in order to correct
the gas quantity during degassing and thus avoid pulsating (sudden
igniting due to lack of oxygen) or insufficient flue gas temperatures.
This is only required for greater deviations from the recommended
fuel or for deviations from the required temperatures for safe
operation of the log wood boiler.
1.
Open the front ash door (1).
2.
Take the flat grate element (4) out toward the front.
✓
The grate lifting bar can be seen in Figure 7/8 - Boiler presetting
as designated with number (3).
3.
Set the grate lifting bar (2) as shown in Figure 7/8 - Boiler
presetting.
4.
Insert the flat grate element (4).
✓
The grate height is now set.
5.
Heat the log wood boiler as described in chapter “4 Using the
HDG Euro”, section “4.6 Lighting and reloading the HDG Euro”.
In the HDG Euro V3.0 with HDG Lambda Control 1 for log wood, the
grate lifter is already installed in a horizontal position!
Figure 7/8 - Boiler presetting