HDG Bavaria GmbH 06/2008
HDG Euro V3.0 with HDG Lambda Control 1 - V 1 - en
2 Safety notes – Intended use
9
The appliance should be inspected regularly and the chimney
cleaned at least annually. More frequent cleaning may be required
and the advice of a qualified chimney sweep should be sought.
Always check for any flue blockage before lighting the stove after a
prolonged shut down.
This appliance has been carefully designed and constructed to give
clean burning with optimum efficiency and safety, but as with all
appliances these standards will not be achieved unless it is installed
and maintained regularly by qualified engineers. It must also be
operated strictly with the procedures given in this manual.
If you are unsure about anything concerning your appliance please
seek professional advice.
Useful Organisations
Basic principles for the construction of the system
Basic principles
The heating system was built using state of the art technology and
conforms to recognised safety regulations. Nevertheless, its use still
incurs the risk of injury or death of the user or a third party or of
adverse effects upon the heating system itself or upon other
material goods.
Have your specialist heating company provide you
with detailed instruction on the operation of the heating system
.
Using the heating system
Only use the heating system if in perfect condition. Use it properly,
as intended, and be aware of safety concerns and the dangers
involved under observance of the Operation Manual. Have any faults
which could impair safety immediately fixed.
Proper and improper manner of operation
Application of the
heating system
The HDG Euro V3.0 with HDG Lambda Control 1 is designed to burn
untreated wood in the form of split logs up to 500 mm (19"), pressed
briquettes and coarse wood chips, coarse grade, cross section of
maximum 1000 mm
2
and not less than 600 m
2
). Varnished, coated or
impregnated wood should never be used for fuel.
Any other application is considered improper use. The manufacturer
will accept no liability for any damage resulting from improper use.
The operating company bears sole responsibility in such cases.
Name
Phone
Web
Solid Fuel Association
0845 601 4406
www.solidfuel.co.uk
The National Association of Chimney Sweeps
01785 811732
www.chimneyworks.co.uk
HETAS Ltd.
0845 634 5626
www.hetas.co.uk
Table 2/1 - Useful Organisations
Содержание Euro V3.0
Страница 1: ...hdg bavaria com HDG Euro V3 0 with HDG Lambda Control 1 Operation Manual V 01 06 2008 ...
Страница 2: ......