HDG Bavaria GmbH 06/2008
HDG Euro V3.0 with HDG Lambda Control 1 - V 1 - en
7 Commissioning the HDG Euro – Commissioning the HDG Euro
67
18.
Confirm using the
Arrow
button.
✓
The minimum buffer tank temperature is set and the menu will
advance to the next setting.
Minimum boiler
temperature
✓
The message “
Min. boiler TK
min
[°C] 60
” appears in the display.
19.
Use the
Plus
or
Minus
button to select the required “minimum
boiler temperature”.
✓
The selected temperature will appear in the display.
20.
Confirm using the
Arrow
button.
The setting is stored and the menu will advance to the next setting.
Minimum flue gas
temperature
✓
The message “
Min. flue gas temp. /
TA
min
[°C] 100
” appears in the display.
21.
Use the
Plus
or
Minus
button to select the appropriate minimum
flue gas temperature.
✓
The selected temperature will appear in the display.
22.
Confirm the minimum flue gas temperature setting with the
Arrow
button.
✓
The minimum flue gas temperature is set and the menu will
advance to the next setting.
Return valve runtime
✓
The message “
Return valve
[sec.] 150
” appears in the display.
23.
Use the
Plus
or
Minus
button to select the runtime for the
installed servo drive for the return valve.
✓
The selected runtime will appear in the display.
24.
Confirm using the
Arrow
button.
✓
The runtime is set and the menu will advance to the next setting.
Loading valve runtime
✓
The message “
Loading valve
[sec.] 150
” appears in the display.
25.
Use the
Plus
or
Minus
button to select the runtime for the
installed servo drive for the loading valve.
✓
The selected runtime will appear in the display.
The “minimum boiler temperature” should not be set to less than
60˚C.
This value is the required lowest temperature setting for the
chimney. Observe the specifications provided by the chimney
designer and the chimney manufacturer.
Please note!
Setting range 120 - 240 seconds.