Connect accumulator:
1. Screw off the accumulator’s tapped plug (1) with a size 8 hex key.
2. Screw adapter (3) onto accumulator (4).
3. Open the ller screw (2) with a size 6 hex key. (1/2 turn)
4. Screw HAWE lling unit DFM 400 onto adapter.
Make sure that the lling unit has an O-ring.
Lay the O-ring into the guide slot (1).
Screw the lling unit's union nut (2) onto the adapter by
hand.
HAWE Hydraulik SE
B 6052-21 -
11
-2021 - 1.7
51/63