1. Extend piston rod
2. Shut down hydraulic locking unit and secure it against inadvertent restarting.
3. Remove any component coverings that obstruct checking.
4. Check and clean piston rod, wiper and rod ends.
5. Afterward, use the care products listed below to protect the locking unit.
6. The locking unit must be replaced if damaged. Get in touch with HAWE Micro Fluid GmbH.
8.2.2 Emergency override
WARNING
Risk of injury in event of inadequate qualication
Improper operation of the emergency override can result in severe injury and damage to property.
►
The emergency override may only be operated by trained personnel or instructed persons.
►
After the emergency override has been operated, the locking, opening and holding function, as well
as the drift, must be checked as per the functional check procedure.
Maintenance intervals
Inspection interval specied by ride manufacturer.
It must be ensured that any damage to the pressure tube and actuating button which leads to a
functional failure of the emergency release is reliably detected. The area around the button must always
be kept clean to prevent dirt from entering the valve. The emergency override valve is better protected
against environmental effects when tted with a rubber cap, and cleaning it is then also much easier.
Aids, tools, materials
■
Type-specic design of the tool to operate the emergency override (page
).
■
Listed cleaning and care products
1. Shut down hydraulic locking unit while it is unlocked (depressurized) and secure it against inadver-
tent restarting.
✓
Type EX/type DL (EX): Piston rod extended
✓
Type RE/DL (RE): Piston rod retracted
2. Remove any component coverings that obstruct checking.
3. Remove the rubber cap.
4. Clean the area around the emergency override button with brake cleaner. Stubborn stains can be
removed with a cloth soaked in universal thinner.
5. After waiting about two minutes for the cleaner to act, press the emergency override button again
ve times.
Use suitable tools.
6. Repeat the last two steps until the emergency override button resets smoothly and with virtually no
friction.
Replace the locking unit if the emergency override button is no longer moving smoothly.
Get in touch with HAWE Micro Fluid GmbH.
7. When you have nished, clean the area around the emergency override button with brake cleaner
several times.
8. Put the rubber cap back in place.
9. Start up the hydraulic locking unit in the ride (chapter
"Starting up the hydraulic locking unit",
8.2.3 Piston rod
Maintenance intervals
Inspection interval specied by ride manufacturer.
36/63
B 6052-21 -
11
-2021 - 1.7
HAWE Hydraulik SE