1620 the “DewK”
81
8 Digital Communications Interface
Command
Description
Refer To
DATa:RECord:OPEN
(<year>,<month>,<day>,<hour>,<minute>,<sec-
ond>[,<year>,<month>,<day>,<hour>,<min-
ute>,<second>)
Opens the range of data for reading
Section 8.4.3.23
DATa:RECord:READ? [<num>]
Returns a group of data
Section 8.4.3.24
DATa:RECord:TIMe?
Returns the data recording timer
Section 8.4.3.25
DATa:RECord:TIMe <num>|MIN|MAX|DEF
Sets the data recording timer
Section 8.4.3.26
FETCh? [<chn>]
Returns the temperature and humidity measurements for the speci-
fied channel
Section 8.4.2.13
FORMat:TDSTamp:STAT?
Returns the state of the date/time stamp for FETCh,MEASure, or
READ command
Section 8.4.2.14
FORMat:TDSTamp:STAT? <bool>
Enables or disables the date/time stamp for FETCh, MEASure, or
READ command
Section 8.4.2.15
INITiate
no action
Section 8.4.4.1
INITiate:CONTinous?
Returns the continuous state (always 1)
Section 8.4.4.2
MEASure? [<chn>]
Returns the temperature and humidity measurements for the speci-
fied channel
Section 8.4.2.16
READ? [<chn>]
Returns the temperature and humidity measurements for the speci-
fied channel
Section 8.4.2.17
ROUTe:CLOSe? [<chn>]
Returns the state of the specified channel
Section 8.4.5.1
ROUTe:CLOSe <chn>
Enables the specified channel
Section 8.4.5.2
ROUTe:OPEN? [<chn>]
Returns the channel state
Section 8.4.5.3
ROUTe:OPEN <chn>
Disables the specified channel
Section 8.4.5.4
SENSor:AVERage?
Returns the state of the measurement averaging
Section 8.4.4.3
SENSor:AVERage <bool>
Enables or disables the measurement averaging
Section 8.4.4.4
SENSor<chn>:LOCK?
Returns the state of the sensor lock for the specified channel
Section 8.4.4.5
SENSor<chn>:LOCK <bool>
Enables or disables the sensor lock for the specified channel
Section 8.4.4.6
SENSor<chn>:IDENtification?
Returns the sensor identification for the specified channel
Section 8.4.4.7
SENSor<chn>:IDENtification <str>
Sets the sensor identification for the specified channel
Section 8.4.4.8
SENSor<chn>:STATus?
Returns the sensor status for the specified channel
Section 8.4.4.9
STATus:ALARm?
Returns and clears the alarm status event
Section 8.4.11.9
STATus:ALARm:CONDition?
Returns the alarm status condition
Section 8.4.11.10
STATus:ALARm:ENABle?
Returns the alarm status enable
Section 8.4.11.11
STATus:ALARm:ENABle <num>|MIN|MAX|DEF
Sets the alarm status enable
Section 8.4.11.12
STATus:MEASure?
Returns and clears the measurement status event
Section 8.4.11.13
STATus:MEASure:CONDition?
Returns the measurement status condition
Section 8.4.11.14
STATus:MEASure:ENABle?
Returns the measurement status enable
Section 8.4.11.15
STATus:MEASure:ENABle <num>|MIN|MAX|DEF
Sets the measurement status enable
Section 8.4.11.16
Alphabetical List Commands continued
Содержание DewK 1620
Страница 1: ...1620 the DewK Thermo Hygrometer User s Guide Rev 4B1801...
Страница 158: ...warranty 10 Z zones display 36 153 Index...