80
Hart Scientific
8 Digital Communications Interface
Command
Description
Refer To
CALCulate<chn>:PARameter<num>:
AVERerage<num>:DATA?
Returns a running statistic for the specified channel
Section 8.4.2.6
CALCulate[<chn>]:PARameter<num>:
AVERerage<num>:TYPE?
Returns statistical type for the specified channel (temperature, hu-
midity, type)
Section 8.4.2.7
CALCulate<chn>:PARameter<num>:RATE?
Returns rate calculation for the specified channel
Section 8.4.2.8
CALCulate[<chn>]:PARameter[<num>]:RATE:TIME?
Returns the rate time span
Section 8.4.2.9
CALCulate[<chn>]:PARameter[<num>]:RATE:TIME
<num>|MIN|MAX|DEF
Sets the rate time span
Section 8.4.2.10
CALCulate[<chn>]:PARameter<num>:RESolution?
Returns the display resolution
Section 8.4.2.11
CALCulate<chn>:PARameter<num>:RESolution
<num>|MIN|MAX|DEF
Sets the display resolution)
Section 8.4.2.12
DATa:DSTat:ENABle?
Returns the state of the daily stats recording enable
Section 8.4.3.1
DATa:DSTat:ENABle <bool>
Enables or disables the daily stats recording enable
Section 8.4.3.2
DATa:DSTat:HOUR?
Returns the daily stats recording time
Section 8.4.3.3
DATa:DSTat:HOUR <num>|MIN|MAX|DEF
Sets the daily stats recording time
Section 8.4.3.4
DATa:DSTat:RENable?
Returns the state of the statistics reset enable
Section 8.4.3.5
DATa:DSTat:RENable <bool>
Enables or disables the statistics reset
Section 8.4.3.6
DATa:DSTat:RHOur?
Returns the statistics reset time
Section 8.4.3.7
DATa:DSTat:RHOur <num>|MIN|MAX|DEF
Sets the statistics reset time
Section 8.4.3.8
DATa:DSTat:RECord:BTIMe? [<num>]
Returns the daily stats record begin time
Section 8.4.3.9
DATa:DSTat:RECord:CLEar
Clears all daily stats records
Section 8.4.3.10
DATa:DSTat:RECord:COUNt? [MAX]
Returns the daily stats record count
DATa:DSTat:RECord:DATE? [<num>]
Returns the daily stats record date
Section 8.4.3.12
DATa:DSTat:RECord:ETIMe? [<num>]
Returns the daily stats record end time
Section 8.4.3.13
DATa:DSTat:RECord:FIND? [<year>,<month>,<day>]
Returns the daily stats record number for the given date
Section 8.4.3.14
DATa:DSTat:RECord:VALue? [<num>,<chn>,<type>]
Returns the daily stats statistical calculation
Section 8.4.3.15
DATa:RECord:CLEar
Clears all recorded data
Section 8.4.3.16
DATa:RECord:FEED:RHUMidity<chn>?
Returns the state of the humidity recording for the specified channel Section 8.4.3.17
DATa:RECord:FEED:RHUMidity<chn> <bool>
Enables or disables the humidity recording for the specified channel Section 8.4.3.18
DATa:RECord:FEED:TEMPerature<chn>?
Returns the state of the temperature recording for the specified
channel
Section 8.4.3.19
DATa:RECord:FEED:TEMPerature<chn> <bool>
Enables or disables the temperature recording for the specified
channel
Section 8.4.3.20
DATa:RECord:FREE?
Returns the recording memory usage
Section 8.4.3.21
DATa:RECord:OPEN?
Returns the number of bytes in the open data set
Section 8.4.3.22
Alphabetical List Commands continued