the fault line output is LOW, but the voltage at the
Test Point is good, then the regulator IC is defective.
If the fault line is output HIGH but there is still a
fault indicated on the ColorStat™ panel, refer to
SECTION Q, LED Board for troubleshooting infor-
mation on the fault circuits.
Decimal
Digit
Binary
Number
Decimal
Number
Binary
Number
0
0000
5
0101
1
0001
6
0110
2
0010
7
0111
3
0011
8
1000
4
0100
9
1001
Table J-1. Decimal to Binary
Power Level
Decimal
BCD (Binary Coded
Decimal)
Maximum Power
0.999
1001 1001 1001
One-half power
0.707
0111 0000 0111
One-fourth power
0.500
0101 0000 0000
One-tenth power
0.316
0011 0001 0110
Zero power
0.000
0000 0000 0000
Table J-2. Power Level Coding
Section J - Analog Input (A35)
888-2297-002
J-5