A-1 Default settings
A-4
A
ppendi
x
Apx
FHA-C 4-wire, wire-saving incremental series (voltage: 100V)
Actuator model No.
FHA-8C
FHA-11C
FHA-14C
Actuator reduction ratio
30
50
100
30
50
100
30
50
100
Combined driver
HA-800A-1C-100
HA-800A-1C-100
HA-800A-1C-100
d13
Applicable actuator
Code
6304
6314
6334
6504
6514
6534
6704
6714
6734
AJ00
Position loop gain
(default)
40
40
40
40
40
40
40
40
40
AJ01
Speed loop gain
(default)
35
35
35
45
45
45
80
80
80
AJ02
Speed loop integral
compensation
(default)
20
20
20
20
20
20
20
20
20
AJ04
In-position range
(default)
10
10
10
10
10
10
10
10
10
SP49
Allowable position
deviation (default)
100
100
100
100
100
100
100
100
100
SP51
Speed input factor
(default)
6000
6000
6000
6000
6000
6000
6000
6000
6000
SP60
Automatic gain
(default)
1
1
1
1
1
1
1
1
1
SP61
Encoder monitor
Output pulses (default)
1
1
1
1
1
1
1
1
1
SP69
Feed-forward control
function setting
0
0
0
0
0
0
0
0
0
FHA-Cmini absolute series (voltage: 200V)
Actuator model No.
FHA-8C
FHA-11C
FHA-14C
Actuator reduction ratio
30
50
100
30
50
100
30
50
100
Combined driver
HA-800A-1D-200
HA-800A-1D-200
HA-800A-1D-200
d13
Applicable actuator
Code
6201
6211
6231
6401
6411
6431
6601
6611
6631
AJ00
Position loop gain
(default)
40
40
40
40
40
40
40
40
40
AJ01
Speed loop gain
(default)
21
21
21
27
27
27
48
48
48
AJ02
Speed loop integral
compensation
(default)
20
20
20
20
20
20
20
20
20
AJ04
In-position range
(default)
150
150
150
150
150
150
150
150
150
SP49
Allowable position
deviation (default)
1500
1500
1500
1500
1500
1500
1500
1500
1500
SP51
Speed input factor
(default)
6000
6000
6000
6000
6000
6000
6000
6000
6000
SP60
Automatic gain
(default)
1
1
1
1
1
1
1
1
1
SP61
Encoder monitor
Output pulses (default)
8192
8192
8192
8192
8192
8192
8192
8192
8192
SP69
Feed-forward control
function setting
0
0
0
0
0
0
0
0
0
FHA-Cmini absolute series (voltage: 100V)
Actuator model No.
FHA-8C
FHA-11C
FHA-14C
Actuator reduction ratio
30
50
100
30
50
100
30
50
100
Combined driver
HA-800A-1D-100
HA-800A-1D-100
HA-800A-1D-100
d13
Applicable actuator
Code
6301
6311
6331
6501
6511
6531
6701
6711
6731
AJ00
Position loop gain
(default)
40
40
40
40
40
40
40
40
40
AJ01
Speed loop gain
(default)
21
21
21
27
27
27
48
48
48
AJ02
Speed loop integral
compensation
(default)
20
20
20
20
20
20
20
20
20
AJ04
In-position range
(default)
150
150
150
150
150
150
150
150
150
SP49
Allowable position
deviation (default)
1500
1500
1500
1500
1500
1500
1500
1500
1500
SP51
Speed input factor
(default)
6000
6000
6000
6000
6000
6000
6000
6000
6000
SP60
Automatic gain
(default)
1
1
1
1
1
1
1
1
1
SP61
Encoder monitor
Output pulses (default)
8192
8192
8192
8192
8192
8192
8192
8192
8192
SP69
Feed-forward control
function setting
0
0
0
0
0
0
0
0
0
Содержание H A - 800A
Страница 60: ...2 6 Wiring the host device 2 21 4 2 2 1 9 8 7 6 9 8 Installation wiring...
Страница 86: ...3 6 Normal operation 3 25 4 3 3 1 9 8 7 6 9 8 Startup...
Страница 152: ...5 8 Connection example in control mode 5 35 1 2 3 4 5 6 7 8 9 10 11 Appe I O signals...
Страница 166: ...6 1 Operating display panel 6 13 11 10 9 4 7 6 5 4 3 2 1 Panel display and operation...
Страница 188: ...7 6 Details of tune mode 7 21 1 2 3 4 5 6 7 8 9 10 11 Appe Status display mode alarm mode tune mode...
Страница 206: ...8 2 Function extension parameter 8 17 1 2 3 4 5 6 7 8 9 10 11 Appe System parameter mode...
Страница 222: ...9 2 Details of test mode 9 15 1 2 3 4 5 6 7 8 9 Test mode...
Страница 270: ...11 2 Warnings and remedial actions 11 17 1 2 3 4 5 6 7 8 9 10 11 Appe Troubleshooting...
Страница 271: ...1 16 Chapter 12 Option Options you can purchase as necessary are explained 12 1 Option 12 1...
Страница 276: ...12 1 Option 12 5 1 2 3 4 5 6 7 8 12 Option...
Страница 310: ...A 6 Control block diagram A 33 Appendix Apx...