7-5 Tune mode
7-12
1
2
3
4
5
6
7
8
9
10
11
Appe
Stat
us di
spl
ay m
ode/
al
ar
m
m
ode/
tune m
ode
7-5
Tune mode
You can read and change parameters relating to actuator operations.
The following items can be changed.
Mode
Code
Parameters
Default
Details
Tune m
ode 1
AJ00
Position loop gain
*1
AJ01
Speed loop gain
*1
AJ02
Speed loop integral compensation
*1
AJ03
Feed-forward gain
0
AJ04
In-position range
*1
AJ05
Attained speed judgment value
l
2000
AJ06
Attained torque judgment value
l
50
AJ07
Zero speed judgment value
10
AJ08
Internal speed command 1
500
AJ09
Internal speed command 2
1000
AJ10
Internal speed command 3
1500
AJ11
Torque limit
100
AJ12
Acceleration time constant
1
AJ13
Deceleration time constant
1
AJ14
External speed command offset
0
AJ15
External torque command offset
0
AJ16
Speed monitor offset
*2
AJ17
Current monitor offset
*2
AJ18
System reservation *3
--
--
AJ19
System reservation *3
--
--
Tune m
ode 2
AJ20
Feed-forward filter
1
AJ21
Load inertia moment ratio
100
AJ22
Torque constant compensation
factor
100
AJ23
Spring constant compensation
factor
100
AJ24
Positioning Automatic Gain
0
AJ25 to 39
System reservation *3
--
--
Tune m
ode 3
AJ40 to 59
System reservation *3
--
--
*1: It varies depending on the applicable actuator.
Refer to the values of applicable actuator that are the targets of Appendix 1 [Default settings].
*2: It varies depending on the driver.
*3: Do not change the parameters that are in the system reserved areas. The default setting of the system
reservation may vary depending on the model/version. If the set values change when the parameters
are transferred between different models, it does not affect the product functions.
To perform the data comparison with the backed up parameter files or writing the backed up parameter
files to the driver using PSF-800 communication software, refer to [10-5. Saving and reading set
values].
Содержание H A - 800A
Страница 60: ...2 6 Wiring the host device 2 21 4 2 2 1 9 8 7 6 9 8 Installation wiring...
Страница 86: ...3 6 Normal operation 3 25 4 3 3 1 9 8 7 6 9 8 Startup...
Страница 152: ...5 8 Connection example in control mode 5 35 1 2 3 4 5 6 7 8 9 10 11 Appe I O signals...
Страница 166: ...6 1 Operating display panel 6 13 11 10 9 4 7 6 5 4 3 2 1 Panel display and operation...
Страница 188: ...7 6 Details of tune mode 7 21 1 2 3 4 5 6 7 8 9 10 11 Appe Status display mode alarm mode tune mode...
Страница 206: ...8 2 Function extension parameter 8 17 1 2 3 4 5 6 7 8 9 10 11 Appe System parameter mode...
Страница 222: ...9 2 Details of test mode 9 15 1 2 3 4 5 6 7 8 9 Test mode...
Страница 270: ...11 2 Warnings and remedial actions 11 17 1 2 3 4 5 6 7 8 9 10 11 Appe Troubleshooting...
Страница 271: ...1 16 Chapter 12 Option Options you can purchase as necessary are explained 12 1 Option 12 1...
Страница 276: ...12 1 Option 12 5 1 2 3 4 5 6 7 8 12 Option...
Страница 310: ...A 6 Control block diagram A 33 Appendix Apx...