11-1 Alarms and remedial actions
11-5
1
2
3
4
5
6
7
8
9
10
11
Appe
Troubl
esh
oot
ing
Alarm
code
Alarm name
Description
Condition at
occurrence
Action
AL40
Overvoltage
The main
circuit voltage
exceeded
approx. 400
VDC.
The alarm
occurs during
operation:
Excessive load inertia moment
→ The built-in regenerative resistor does not
function. Connect short bar to R1 and R3
terminals.
→ Connect a regenerative resistor to the R1
and R2 terminals.
→ Increase the deceleration time.
→ Lower the maximum speed.
→ Lower the load inertia moment.
Overvoltage detection circuit error
→ Contact our sales office.
AL41
Regenerative
resistor
overheat
The thermal
switch installed
on the
regenerative
resistor
actuated.
The alarm
occurs during
deceleration:
Insufficient regenerative resistor capacity
→ Install an external regenerative resistor to
raise the regenerative absorption
capacity.
→ When using an external regenerative
resistor in HA-800A-24, set [SP64:
Regenerative resistor selection] to [1:
Use external regenerative resistor].
Regenerative energy processing circuit
error
→ Contact our sales office.
The alarm
occurs after
turning the main
circuit power ON
(HA-800A-24):
The regenerative resistor is not properly
wired or not connected.
→Connect the regenerative resistor correctly.
When an
external
regenerative
resistor is used
(HA-800A-24):
The regenerative resistor is not properly
wired or not connected.
→Connect the regenerative resistor correctly.
The parameter setting of regenerative
resistor selection (SP64) is wrong.
→ Change the setting of system parameter
SP64 and select an external regenerative
resistor.
AL42
Overregenerati
on
(HA-800A-24)
A regenerative
resistor
absorbed
significantly
excessive
regenerative
energy.
The alarm
occurs during
deceleration:
Insufficient regenerative resistor capacity
→ Install an external regenerative resistor to
raise the regenerative absorption
capacity and change the setting of
system parameter SP64.
Regenerative energy processing circuit
error
→ Contact our sales office.
(Replace the HA-800A driver.)
Load inertia exceeds the adaptive range.
→ Review the configuration and use the
resistor with load inertia within the
adaptive range.
→ Suppress the rotation low to reduce
regenerative energy.
The alarm
occurs after
turning the main
circuit power
ON:
The regenerative resistor is not properly
wired or not connected.
→ Connect the regenerative resistor
correctly.
→ Connect a short bar correctly when using
a built-in regenerative resistor.
Содержание H A - 800A
Страница 60: ...2 6 Wiring the host device 2 21 4 2 2 1 9 8 7 6 9 8 Installation wiring...
Страница 86: ...3 6 Normal operation 3 25 4 3 3 1 9 8 7 6 9 8 Startup...
Страница 152: ...5 8 Connection example in control mode 5 35 1 2 3 4 5 6 7 8 9 10 11 Appe I O signals...
Страница 166: ...6 1 Operating display panel 6 13 11 10 9 4 7 6 5 4 3 2 1 Panel display and operation...
Страница 188: ...7 6 Details of tune mode 7 21 1 2 3 4 5 6 7 8 9 10 11 Appe Status display mode alarm mode tune mode...
Страница 206: ...8 2 Function extension parameter 8 17 1 2 3 4 5 6 7 8 9 10 11 Appe System parameter mode...
Страница 222: ...9 2 Details of test mode 9 15 1 2 3 4 5 6 7 8 9 Test mode...
Страница 270: ...11 2 Warnings and remedial actions 11 17 1 2 3 4 5 6 7 8 9 10 11 Appe Troubleshooting...
Страница 271: ...1 16 Chapter 12 Option Options you can purchase as necessary are explained 12 1 Option 12 1...
Страница 276: ...12 1 Option 12 5 1 2 3 4 5 6 7 8 12 Option...
Страница 310: ...A 6 Control block diagram A 33 Appendix Apx...