1-5 Motor shaft brake
26
1
2
3
4
5
6
7
8
9
10
11
付
Ou
tlin
e
SG
Model
Item
SHA40A
SHA58A
51
81
101
121
161
81
101
121
161
Type
Dry non-excitation actuation type (without power-saving control)
Brake excitation voltage
V
DC24V ± 10% (no polarity)
*1
Current consumption
during suction (at 20
℃
)
A
rms
0.7
0.9
Current consumption
during holding (at 20
℃
)
A
rms
Same as current consumption during suction
Holding torque
*3
Nm
204
324
404
484
644
1220
1520
1820
2420
kgf·m
21
33
41
49
66
124
155
185
246
Inertia moment
*3
(Actuator total)
(With brake)
(GD
2
/4)
kg·m
2
6.1
15
24
34
61
106
165
237
420
(J)
kgf·cm·s
2
62
157
244
350
619
1090
1690
2420
4290
Mass
(with brake)
*4
kg
10.7
32
Allowable number of
normal stops
*5
100,000 times
Allowable number of
emergency stops
*6
200 times
Model
Item
SHA65A
81
101
121
161
Type
Dry non-excitation actuation type (without
power-saving control)
Brake excitation voltage
V
DC24V±10% (no polarity)
*1
Current consumption
during suction (at 20
℃
)
A
rms
0.9
Current consumption
during holding (at 20
℃
)
A
rms
Same as current consumption during
suction
Holding torque
*3
Nm
1220
1520
1820
2420
kgf·m
124
155
185
246
Inertia moment
*3
(Actuator total)
(With brake)
(GD
2
/4)
kg·m
2
120
187
268
475
(J)
kgf·cm·s
2
1230
1910
2740
4850
Mass
(with brake)
*4
kg
40
Allowable number of
normal stops
*5
100,000 times
Allowable number of
emergency stops
*6
200 times
CG
type
Model
Item
SHA20A
SHA25A
50
80
100
120
160
50
80
100
120
160
Type
Dry non-excitation actuation type (without power-
saving control)
Dry non-excitation actuation type
(with power-
saving control)
Brake excitation
voltage
V
DC24V
±
10%(no polarity)
*1
Current consumption
during suction (at
20
℃
)
A
rms
0.37
0.8
*2
Current consumption
during holding (at
20
℃
)
A
rms
Same as current consumption during suction
0.3
Holding torque
*3
Nm
30
48
60
72
96
50
80
100
120
160
kgf·m
3.1
4.9
6.1
7.3
9.8
5.1
8.2
10
12
16
Inertia moment
*3
(Actuator total)
(With brake)
(GD
2
/4)
kg·m
2
0.23
0.6
0.94
1.3
2.4
0.60
1.5
2.4
3.4
6.1
(J)
kgf·cm·s
2
2.4
6.1
9.6
14
24
6.1
16
24
35
62
Mass
(with brake)
*4
kg
2.7
4.1
Allowable number of
normal stops
*5
100,000 times
Allowable number of
emergency stops
*6
200 times
Содержание SHA CG Series
Страница 1: ...AC Servo Actuator SHA SG and CG series manual ISO14001 Hotaka plant ISO9001...
Страница 93: ...Chapter 4 Options This chapter explains the options available for the SHA series actuator 4 1 Options 94...
Страница 95: ...Options 95 1 2 3 4 Apx 6 7 8 9 10 11 Appendix Outline drawing of the actuator with an optional stand Nameplate...
Страница 100: ...Options 100 1 2 3 4 Apx 6 7 8 9 10 11 Appendix Appendix A 1 Unit conversion 101 A 2 Calculating inertia moment 103...
Страница 107: ......