1-11 Direction of rotation
50
1
2
3
4
5
6
7
8
9
10
11
付
Ou
tlin
e
1-11
Direction of rotation
SG/HP
As a default, Forward rotation direction of the actuator is defined as counterclockwise (CCW)
rotation as viewed from the load shaft when a Forward command (FWD command pulse) is given
to a SHA series actuator from a HA-800 driver
This rotation direction can be changed on the HA-800 driver by selecting [SP50: Command polarity setting]
under [System parameter mode 3].
Setting of [SP50: Command polarity setting]
Set
value
FWD command
pulse
REV command
pulse
Setting
0
CCW
(counterclockwise)
direction
CW (clockwise)
direction
Default
1
CW (clockwise)
direction
CCW
(counterclockwise)
direction
CG
As a default, the rotation direction is defined as clockwise (CW) rotation as viewed from the output shaft when a
FWD command pulse is given from a HA-800 driver.
This rotation direction can be changed on the HA-800 driver by selecting [SP50: Command polarity setting] under
[System parameter mode 3].
Setting of [SP50: Command polarity setting]
Set
value
FWD command
pulse
REV command
pulse
Setting
0
CW
(clockwise) direction
CCW
(counterclockwise)
direction
Default
1
CCW
(counterclockwise)
direction
CW
(clockwise) direction
Counterclockwise rotation direction
Содержание SHA CG Series
Страница 1: ...AC Servo Actuator SHA SG and CG series manual ISO14001 Hotaka plant ISO9001...
Страница 93: ...Chapter 4 Options This chapter explains the options available for the SHA series actuator 4 1 Options 94...
Страница 95: ...Options 95 1 2 3 4 Apx 6 7 8 9 10 11 Appendix Outline drawing of the actuator with an optional stand Nameplate...
Страница 100: ...Options 100 1 2 3 4 Apx 6 7 8 9 10 11 Appendix Appendix A 1 Unit conversion 101 A 2 Calculating inertia moment 103...
Страница 107: ......