6.2 Operation with activated timing
If time control is activated in the eCB1 module, the charging process will start as
soon as the issued point of time is reached. Outside of the issued point of time
the charging socket is marked as “reserved” as long as the charging cable is
plugged into the charging socket. In that case the LED Display continues to glow
in green but changes to glow in blue as soon as the charging process starts.
PLEASE NOTE!
If the cable is unplugged during the reserved time, the reservation will
be deleted for the respective charging plug socket. Then you need to
register again.
Time control is activated through the eCB1 module and has to comprise of a
fixed time period (Start time- End time). Additionally, individual weekdays can be
activated or deactivated for time control.
Mark individual RFID-Tags as “Master” to temporarily bypass the time control.
Charging processes activated by these tags ignore the set time period and
activate the charging slot immediately.
PLEASE NOTE!
A flawless time control can only function permanently if the eCB1
module has access to a time server (NTP)!
7.
The charging process will not be terminated by the charging station but only by
the vehicle itself. Based on communication between the cPH1 and your vehicle,
the charging station will give notification by switching the LED colour from blue
back to green. This is to signify that you can remove the charging cable. Upon
ending the charging process, pull the cable out of the socket of your EV and out
of your cPH1. Should the EV still not be completely charged please contact the
service partner of your vehicle.
PLEASE NOTE!
Should any errors or malfunction occur during or after the charging
process, it will be indicated on the LED-Display of the charging station.
Chapter “Operation Status” on page 24 describes how to recognize the
operation status and/or error status and which actions are
necessary to be taken.
PLEASE NOTE!
If time control is activated in the eCB1 module, an ongoing charging
process will be terminated early upon reaching the end of the fixed
time period regardless of its battery condition. Further information can
be found on page 25.
Instruction Manual
cPH1
charging station
Version: 1.2.4
22