In order to connect your charging station to the power line please proceed as follows:
1
Once again make sure that all circuit breakers and all fault-current-circuit
breakers in the lead are deactivated.
2
If not already done, take off the cover by
2.1
unscrewing the two screws from the lower part of the charging station.
2.2
Then carefully lift the cover and remove it.
2.3
In order to remove the LED-Display fully first lift it slightly. Just so you
can unplug it.
3
Turn off all circuit breakers and all fault-current-circuit-breakers inside the
charging station (switch position 0 OFF).
4
Insert the lead from below into the respective cable glands. Clamp the
stripped glands of the lead into the lead terminal blocks according to the
labels (6mm²).
4.1 Single lead:
4.2 Double lead:
Description
Colour of core
Label
Live conductor Phase 1
BROWN
EUROFUSE NH00/000 63A
Live conductor Phase 2
BLACK
EUROFUSE NH00/000 63A
Live conductor Phase 3
GREY
EUROFUSE NH00/000 63A
Neutral
BLUE
BLUE CONDUCTOR
Protective conductor
GREEN-YELLOW
GREEN-YELLOW CONDUCTOR