11 - Fault finding
11.11
107 Alarm
Slant angle sensor fault
Alarm is active when 2.2.4.3 Slant mirror is enabled
and/or if 2.2.4.4 Slant in steps is enabled.
The alarm is generated, if the sensor signal is less
than0.2 Volt or exceeds 4.8 Volt.
Check sensor and cable on pendulum.
Disable HeadLandAssist.
Disable Slant in steps.
115
108 Alarm
Boom height sensor fault
Alarm is active when 2.2.4.2 Boom height at
headlands is enabled.
The alarm is generated, if the sensor signal is less
than0.2 Volt or exceeds 4.8 Volt.
116
109 Alarm
Pressure sensor alarm
Alarm is active when Menu E8.1.7.1 is “Active”
The alarm is generated, if the sensor signal on AI26
(J10_33, J11_33) is less than 3mA or exceeds 21mA.
Check connection to boom pressure sensor at
distribution valve junction box.
117
110 Alarm
JobCom Resetting
Refer to HC 6500 service manual.
124
111 Alarm
JobCom Resetting Done
Refer to HC 6500 service manual.
125
112 Changed
Flat 1
Level 1
Hilly 5
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7, the setbox TWIN
buttons are dedicated to select the Dynamic center
setting. The information pops up when a button
has been pushed.
Defines current Dynamic center setting for the
TERRA FORCE boom.
Flat means the boom is free hanging.
Hilly means the boom will follow the sprayer
movements.
118
113 Changed
Flat 1
Level 2
Hilly 5
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7, the setbox TWIN
buttons are dedicated to select the Dynamic center
setting. The information pops up when a button
has been pushed.
Defines current Dynamic center setting for the
TERRA FORCE boom.
Flat means the boom is free hanging.
Hilly means the boom will follow the sprayer
movements.
119
114 Changed
Flat 1
Level 3
Hilly 5
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7, the setbox TWIN
buttons are dedicated to select the Dynamic center
setting. The information pops up when a button
has been pushed.
Defines current Dynamic center setting for the
TERRA FORCE boom.
Flat means the boom is free hanging.
Hilly means the boom will follow the sprayer
movements.
120
115 Changed
Flat 1
Level 4
Hilly 5
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7, the setbox TWIN
buttons are dedicated to select the Dynamic center
setting. The information pops up when a button
has been pushed.
Defines current Dynamic center setting for the
TERRA FORCE boom.
Flat means the boom is free hanging.
Hilly means the boom will follow the sprayer
movements.
121
116 Changed
Flat 1
Level 5
Hilly 5
When TERRA FORCE boom hydraulics set-up has
been selected in menu E8.6.3.7, the setbox TWIN
buttons are dedicated to select the Dynamic center
setting. The information pops up when a button
has been pushed.
Defines current Dynamic center setting for the
TERRA FORCE boom.
Flat means the boom is free hanging.
Hilly means the boom will follow the sprayer
movements.
122
117 Warning
D-center incorrect position
Time-out on sensor signal AI25.
TERRA FORCE boom hydraulics set-up has been
selected in menu E8.6.3.7
Buttons has been activated to move the Dynamic
center.
The selected setting has not been reached within
10 seconds.
Reset by keypress “enter” or attempt to move
Dynamic center.
Attempt to move Dynamic center cylinder did not
succeed within the given time frame.
Check the hydraulics connections and pressure.
Check Dynamic center position sensor.
37
118 Warning
Pendulum locking failed.
Time-out on sensor signal AI1 when attempting to
lock.
See table “TerraForce Pendulum lock” in terminal
specification xxxx
Reset by attempt to lock.
Attempt to move Pendulum lock cylinder did not
succeed within the given time frame.
Check the hydraulics connections and pressure.
Check Pendulum lock position sensor adjustment.
5
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......