11 - Fault finding
11.10
90
Reminder
Grease misc.
Periodically, period defined in extended menu.
(Only checked at power up)
The track system now needs to be lubricated.
Yellow labels indicate lubrication points otherwise
see operators’ manual.
100
91
Reminder
Miscellaneous service
Periodically, period defined in extended menu.
(Only checked at power up)
See operators’ manual for specific sprayer service.
101
92
Reminder
Check nozzles
Periodically, period defined in extended menu.
(Only checked at power up)
You need to check the individual nozzle flow per
minute.
A stopwatch and good quality measuring jug is
needed.
Do the test with clean water.
Nozzles with over 10% of rated new capacity must
be discarded.
102
93
Reminder
Stop watch is zero
Stop watch is zero
103
94
Changed
Track in manual
Operator has put Track in manual
104
95
Changed
Track in auto
Operator has put Track in auto
105
96
Changed
Track is locked
Operator has locked Track
106
97
Changed
Reversing
Operator is reversing
107
98
Changed
Track unlocked
Lock is detected released.
Hydraulic pressure established. Mis adjusted lock
sensor.
108
99
Alarm
PrimeFlow data cable weakness JobCom does not receive the data it sends.
Shift the relay to Full duplex (transmit to both ends).
Data cable defect is only detected at Half duplex
(listen only right end).
No further Data cable defect are detected at Full
duplex (transmit to both ends).
PrimeFlow bus cable fault is detected.
A failure handling circuit is enabled.
PrimeFlow is in full operation.
35
100 Alarm
Low PrimeFlow voltage
JobCom measure PrimeFlow supply voltage after
fuse for left and right boom part at AI11 and AI12.
Alarm occur when voltage is below 14 volts.
A fuse is open or too many rapid shifts on and off of
sections has drained the power supply.
36
101 Warning
PrimeFlow power cable defect
Low power warning from SMCU, when supply is re-
established.
First low power warning received after power up of
system is not valid.
First low power warning received after “Low voltage
on supercap” is not valid.
Poor power wiring to PrimeFlow computers. One of
the 2 power lines are disconnected or connectors
are corroded and gives high resistance.
109
102 Warning
PrimeFlow computer defect
SMCU does not reply on status.
No status request while “Low voltage on supercap”
occurs.
Internal fault in PrimeFlow computer. Can also be
caused by 2 or more defects in PrimeFlow data
cable. Check for PrimeFlow data cable weakness.
110
103 Warning
Fold with unlocked pendulum
When pressing FoldCenterIn, FoldLeftIn or
FoldRightIn and pendulum is unlocked.
Fold with unlocked pendulum.
111
104 Warning
Boom wing loose
Buttons FoldLeftIn or FoldRightIn are not pressed
but the 4 sensors on outer boom wings change
from “In spray” to “Not in spray” respectively when
they change from “In transport” to “Not in
transport”.
Boom wing loose.
112
105 Changed
Agitation in Auto
Forward speed > 0.5 km/h and Main On/Off = On Agitation in Auto
113
106 Warning
Regulation valve in end-stop
Warning appears when pressure regulation
algoritm tries to close Regulation valve to increase
pressure, but encoder does not give any signals, as
micro switch has turned of motor.
Alarm should not appear at self test at start up.
Pressure regulation is unchanged.
JobCom detected that pressure regulation valve
does not turn and cannot close and increase
pressure and flow any further.
Increase PTO RPM.
Review flow used for agitation.
Check for internal leakages.
114
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......