11 - Fault finding
11.6
09
Alarm
Track Front sensor failure
The alarm is generated, if the sensor signal is less
than 0.2V or exceeds 4.8V.
Automatic tracking is aborted until the system has
been rebooted.
SafeTrack shifted to manual.
Auto is disabled.
Track front sensor failing.
Automatic tracking is aborted.
Manual tracking and “Align” function is possible.
Pressing “Enter will remove the alarm from the
display until the system has been rebooted.
16
10
Alarm
Track Rear sensor failure
The alarm is generated, if the sensor signal is less
than 0.5V or exceeds 4.5V.
SafeTrack shifted to manual.
Auto and Align is disabled.
Track Rear sensor failure.
Automatic tracking is aborted until the system has
been rebooted.
If “Align” mode is selected, no movement takes
place, but trapeze is attempted locked.
Manual tracking still possible.
17
11
Alarm
Agitation valve fault
Error detection not active, profet error detection
not used.
On fault following occurs:
AutoWash disabled
AutoFill disabled
Used by Autowash/AutoFill
Agitation valve fault. Motor disconnected. Motor
short circuit or blocked. Sensor failing.
18
12
Alarm
Reserved
Reserved, replaced by ID154-159
Error detection not active, profet error detection
not used.
On fault following occurs:
AutoWash allowed
AutoFill disabled
Clear alarm by reboot
Used by Autowash/AutoFill
Fill valve fault. Motor disconnected. Motor short
circuit or blocked. Sensor failing.
19
13
Alarm
Fluid system fault
When suction SmartValve is on other port than
RinseTank and RinseTank flow exceed 10 l/min.
On fault following occurs:
AutoWash disabled.
AutoFill disabled.
Used by Autowash/AutoFill
Illegal flow is detected in Sections line or in
RinseTank line.
20
14
Alarm
No RinseTank flow
Error detection.
On fault following occurs:
AutoWash disabled.
AutoFill allowed.
Clear alarm by RinseTank full switch or flow from
RinseTank
Used by Autowash/AutoFill
RinseTank empty or no rinse water flow due to
other reasons.
21
15
Alarm
Reserved
Reserved, replaced by ID154-159
Error detection not active, profet error detection
not used.
On fault following occurs:
AutoWash disabled
AutoFill disabled
Used by Autowash/AutoFill
PressureValve fault. Motor disconnected. Motor
short circuit or blocked. Sensor failing.
22
16
Alarm
Reserved
Reserved, replaced by ID141-145
Error detection not active, profet error detection
not used.
On fault following occurs:
AutoWash disabled
AutoFill allowed
Used by Autowash/AutoFill
Regulation valve fault. Motor disconnected. Motor
short circuit or blocked. Sensor failing.
23
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......