11 - Fault finding
11.9
61
Warning
Speed too high
Speed too high (limit set in menu 2.5.5.1).
Decrease speed. Pressure will be too high.
71
62
Warning
Speed too low
Speed too low (limit set in menu 2.5.5.2).
Increase speed if safe. Pressure will be too low.
72
63
Warning
Appl. volume too high
Application volume too high (% limit set in menu). Increase speed if safe or change nozzle size.Check
regulation valve hoses and filters.
73
64
Warning
Appl. volume too low
Application volume too low (% limit set in menu). Decrease speed or change nozzle size. Check
regulation valve.
74
65
Warning
Fan speed too high
Fan speed too high (limit set in menu 2.5.4.1).
Reduce fan speed
75
66
Warning
Fan speed too low
Fan speed too low (limit set in menu 2.5.4.2).
Increase fan speed
76
67
Warning
PTO speed too low
PTO rev. too low (limit set in menu).
Increase PTO speed
77
68
Warning
PTO speed too high
PTO rev. too high (limit set in menu).
Decrease PTO speed
78
69
Warning
Ladder not up
Raise ladder, to avoid damage to ladder or crop.
79
70
Warning
Wind Speed too high
Wind Speed too high (limit set in menu).
Stop spraying or consider other nozzle types like
HARDI® LowDrift.
80
71
Warning
81
72
Warning
82
73
Warning
83
74
Warning
84
75
Warning
Opt. sensor 1 too high
Limit set in menu.
This will be help text
85
76
Warning
Opt. sensor 1 too low
Limit set in menu.
This will be help text
86
77
Warning
Opt. sensor 2 too high
Limit set in menu.
This will be help text
87
78
Warning
Opt. sensor 2 too low
Limit set in menu.
This will be help text
88
79
Warning
Opt. sensor 3 too high
Limit set in menu.
This will be help text
89
80
Warning
Opt. sensor 3 too low
Limit set in menu.
This will be help text
90
81
Warning
Opt. sensor 4 too high
Limit set in menu.
This will be help text
91
82
Warning
Opt. sensor 4 too low
Limit set in menu.
This will be help text
92
83
Reminder
Aborted by keypress
Upon press of softkey
Used by Autowash/AutoFill
AutoWash is Aborted by keypress.
93
84
Reminder
Aborted by exception #
Aborted by exception, then show number from AW
source code
Previously AutoWash completed
AutoWash is completed
94
85
Reminder
FastFiller valve high friction
After valve self test
AutoAgitation valve has high friction or poor
cabling. Valve will fail within some time. Arrange
repair.
95
86
Reminder
Pressure Valve high friction
After valve self test
PressureValve has high friction or poor cabling.
Valve will fail within some time. Arrange repair.
96
87
Reminder
Suction Valve high friction
After valve self test
SuctionValve has high friction or poor cabling. Valve
will fail within some time. Arrange repair.
97
88
Reminder
Check filters and brakes
Periodically, period defined in extended menu.
(Only checked at power up)
It is now time to check the suction and pressure
filters.
The Cyclone pressure filter is hidden under the grey
right-hand cowling at the front of the sprayer.
Check line and nozzle filters too.
Check brakes.
98
89
Reminder
Grease boom and track
Periodically, period defined in extended menu.
(Only checked at power up)
The boom now needs to be lubricated.
Yellow labels indicate lubrication points other- wise
see operators manual.
99
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......