3 - Description
3.25
4. 5.
5. 7. 1
Boom flow sensor
4. 5.
5. 7. 2
EVC change deviation
4. 5.
5. 7. 3
Reg V. end to end T.
4. 5. 5.
8
JobCom voltage monitor
12 V battery 5 V sensor max min hold
4. 5.
5. 8. 1
12 V battery max
4. 5.
5. 8. 2
12 V battery min
4. 5.
5. 8. 3
5 V battery max
4. 5.
5. 8. 3
5 V battery min
4. 5. 6
PrimeFlow SMCU status
See nozzle position, nozzle order, counts of data error power error
4. 5. 6.
1
First nozzle for SMCU
Position of first nozzle on boom counted from left
4. 5. 6.
2
SMCU 2 or 3 nozzle
Produced or reprogrammed. SMCU with 3 cables could be changed to 2 nozzles
4. 5. 6.
3
Nozzle order
Show --- when connected in normal order Short Medium Long from left -
4. 5. 6.
4
Count of data error
Times were SMCU did not respond to alive telegram. C to reset counters
4. 5. 6.
5
Count of power error
Times were SMCU shot down due to low voltage. C to reset counters
4. 5. 6.
6
SMCU version
View SMCU versions
4. 5. 7
PrimeFlow motor status
4. 5. 7.
1
Motor 1-90 disconnect
Motor or connector disconnected Press C to reset
4. 5. 7.
2
Motor 91-180 disconnect
Motor or connector disconnected Press C to reset
4. 5. 7.
3
Motor 1-90 shorted
Motor or connector short circuited Press C to reset
4. 5. 7.
4
Motor 91-180 shorted
Motor or connector short circuited Press C to reset
4. 5. 7.
5
Motor 1-90 blocked
Motor connection ok, but motor cannot move. Press C to reset
4. 5. 7.
6
Motor 91-180 blocked
Motor connection ok, but motor cannot move. Press C to reset
4. 6
Speed simulation
Key in speed value. To disable simulation key in 0 or power off
4. 7
Emergency
4. 7. 1
Track align
Emergency only. Align sprayer and fold boom, in case a sensor is defect
4. 7. 1.
1
Front sensor
4. 7. 1.
2
Front sensor
4. 7. 1.
3
Rear sensor
4. 7. 1.
4
Rear sensor
4. 7. 1.
5
Boom sensor 1
4. 7. 1.
6
Boom sensor 1
4. 7. 1.
7
Lock sensor
4. 7. 1.
8
Lock sensor
4. 7. 1.
9
SafeTrack mode
4. 7. 2
Boom fold
Emergency only. Manual lock and fold boom, in case a sensor is defect
4. 7. 2.
1
Dynamic center pos.
4. 7. 2.
2
Dyn. center
4. 7. 2.
3
Pendulum lock
4. 7. 2.
4
Pend. unlock
4. 7. 2.
5
Boom sensor 1
4. 7. 2.
6
Boom sensor 1
4. 7. 2.
7
Boom height status
4. 7. 2.
8
Boom height
4. 7. 2.
9
Boom hydraulics
4. 8
Computer CAN status
Menus for a diagnostic system check. Counter of errors. SW HW versions
4. 8. 1
Operating status all computer
Computer detail screens show details in case of faults
4. 8. 1.
1
Terminal HC 6500
4. 8. 1.
2
JobCom HC 6100
4. 8. 1.
3
Grip HC 6300
4. 8. 1.
4
SetBox HC 6400
4. 8. 1.
5
FluidBox HC 6200
4. 8. 2
Software versions all computer
Computer detail screens show details in case of faults
4. 8. 2.
1
JobCom HC 6100
4. 8. 2.
2
Grip HC 6300
4. 8. 2.
3
SetBox HC 6400
4. 8. 2.
4
FluidBox HC 6200
4. 8. 3
Hardware versions all computer
Computer detail screens show details in case of faults
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......