11 - Fault finding
11.14
153 Reminder
AutoWash completed xx cycles
When program is completed
Used by Autowash/AutoFill
AutoWash is completed
AUTOWASH_CYCLE_COMPLITED
154 Warning
FastFiller valve motor fault
Sensor does not change 0.5 volt when motor is
activated for 1 sec
Or Valve do not get into position within 4 sec
Or verify speed 50 mV /100 msec
Beware of blind zone
See also alert ID13
Used by Autowash/AutoFill
FAST_FILL_VALVE_MOT_FAULT
155 Warning
FastFiller valve sensor fault
Sensor changes more than 100 mV when motor is
not activated
Or Speed below 50 mV /100 msec
Used by Autowash/AutoFill
FAST_FILL_VALVE_SENS_FAULT
156 Warning
PressureValve motor fault
Sensor does not change when motor is activated
Used by Autowash/AutoFill
PRESSURE_VALVE_MOT_FAULT
157 Warning
PressureValve sensor fault
Sensor changes when motor is not activated
Used by Autowash/AutoFill
PRESSURE_VALVE_SENS_FAULT
158 Warning
SuctionValve motor fault
Sensor does not change when motor is activated
Used by Autowash/AutoFill
SUCTION_VALVE_MOT_FAULT
159 Warning
Suction Valve sensor fault
Sensor changes when motor is not activated
Used by Autowash/AutoFill
SUCTION_VALVE_SENS_FAULT
160 Alarm
Illegal AutoWash Setup
Illegal pumps chosen
Autowash will not start (preconditions not fulfilled)
Used by Autowash/AutoFill
ILLEGAL_AWASH_SETUP
161 Warning
Pump RPM too low
Increase
Pump RPM is below table limits
Increase to go to Pause
Used by Autowash/AutoFill
PUMP_RPM_TOO_LOW
162 Warning
Pump RPM too high
Decrease
Pump RPM is above table limits
Decrease to go to Pause
Used by Autowash/AutoFill
PUMP_RPM_TOO_HIGH
163 Warning
Increase pump flow
With EFC or PrimeFlow: When valve is closed and
regulator is in state 6x
With EVC: When valve is in closed end stop and flow
is over threshold
Used by Regulation
INC_PUMP_FLOW,
164 Warning
Reduce pump flow
With EFC or PrimeFlow: When valve is open and
regulator is in state 6x
With EVC: When valve is in open end stop and flow
is over threshold
Used by Regulation
RED_PUMP_FLOW,
165 Warning
Jobcom Fram defect
Write data to FRAM then read
If read data is different from write data
Clear alarm by power off p power on
ID
Type
Text at display detail
Criteria for fault
Operations disabled
Full screen Help text
Pr
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......