3 - Description
3.15
Menus
Full menu structure
÷
NOTE! Blank fields are menus without name or description.
÷
NOTE! Menus marked with a
are not for ISOBUS terminals.
Menu number
Menu name
Description / Help text
1
Daily settings
Most used settings e.g. desired rate, tank contents and register number
1. 1
Volume rate
Use arrow keys or numeric keys to set the desired volume rate
1. 2
Tank contents
To change displayed tank contents. Use arrow keys or numeric keys to set
1. 3
Select register
Use register 1 to 99 for job. Scroll to register, then press Enter to show data
1. 3. 1
1. 3. 1.
1
Show register spray data 1
Press C for 5 sec to reset register. Enter to see screen 2, ESC to leave
1. 3.
1. 1. 1
Start date
1. 3.
1. 1. 2
Start time
1. 3.
1. 1. 3
End date
1. 3.
1. 1. 4
End time
1. 3. 1.
2
Show register spray data 2
Press C for 5 sec to reset register, Enter to see screen 1, ESC to leave
1. 3.
1. 2. 1
Volume applied
1. 3.
1. 2. 2
Area covered
1. 3.
1. 2. 3
Average spray speed
1. 3.
1. 2. 4
Maximum spray speed
1. 3.
1. 2. 5
Travelled spray dist
1. 3.
1. 2. 6
Time used spraying
1. 3.
1. 2. 7
Work rate
1. 3.
1. 2. 8
Average volume rate
1. 4
Volume rate: Preset high
Rate selected with1 press on the arrow up-key
1. 5
Volume rate: Preset low
Rate selected with1 press on the arrow down-key
2
Setup
Customizing of display, automatic functions, clock, alarms, registers, etc
2. 1
Display readout
Customizes the 4 small display readouts
2. 1. 1
Show upper middle
2. 1. 1.
01
Programmed volume rate
Shows Programmed volume rate
2. 1. 1.
02
Boom flow
Boom flow rate per minute sprayed out through the boom
2. 1. 1.
03
time
Actual time
2. 1. 1.
04
Work rate
Rate shown in hectare per hour or acre per hour
2. 1. 1.
05
Actual volume rate
Actual rate in liter per hectare or gallon per acre
2. 1. 1.
06
Tank contents
Main tank contents
2. 1. 1.
07
Speed
Driving speed
2. 1. 1.
08
Volume sprayed
Readouts for Volume sprayed in currently active register
2. 1. 1.
09
Area sprayed
Readouts for Area sprayed in currently active register
2. 1. 1.
10
Active boom size
Active boom size including end nozzle
2. 1. 1.
11
Pressure
Displays spray pressure if sensor is fitted
2. 1. 1.
12
Fan speed
Displays Twin fan speed if sensor is fitted
2. 1. 1.
13
Wind Speed
Displays wind speed if sensor is fitted
2. 1. 1.
14
Pendulum lock status
Displays reading of pendulum lock sensor if fitted
2. 1. 1.
15
Pendulum unlock status
Displays reading of pendulum unlock sensor if fitted
2. 1. 1.
16
Dynamic center position
Displays Dynamic center position sensor if fitted
2. 1. 1.
17
Spray pump rev
Displays revolutions if sensor is fitted
2. 1. 1.
18
Extra sensor 1F
Readout from extra sensor 1 frequency
2. 1. 1.
19
Extra sensor 2F
Readout from extra sensor 2 frequency
2. 1. 1.
20
Extra sensor 3A
Readout from extra sensor 3 analog
2. 1. 1.
21
Extra sensor 4A
Readout from extra sensor 4 analog
2. 1. 1.
22
Voltmeter
Displays system voltage. Useful when fault finding
2. 1. 1.
23
Agitation
Agitation valve opening
grey box
Содержание ISOBUS VT
Страница 2: ......
Страница 4: ......
Страница 8: ...Table of contents TOC 4 ...
Страница 10: ...1 Welcome 1 2 ...
Страница 12: ...2 Safety notes 2 2 ...
Страница 48: ...5 Menu 1 Daily settings 5 2 ...
Страница 52: ...6 Menu 2 Setup 6 4 ...
Страница 74: ...8 Menu 4 Toolbox 8 4 ...
Страница 78: ...10 Maintenance 10 2 ...
Страница 103: ......