![HANGCHA XE Series Скачать руководство пользователя страница 61](http://html2.mh-extra.com/html/hangcha/xe-series/xe-series_operation-and-maintenance-manual_3662064061.webp)
57
Voltage: Battery current voltage value
Charging time: Accumulated charging time
Total current: Charger max output current value when
operating
10) After charging is complete the indicator light stays on and the screen displays charging completed.
Disconnect the charger's AC circuit breaker, unplug the AC input connector, and then unplug the battery
connector.
Note: Improper operation can damage the battery or charger, or lead to other risks.
5. Regular inspection instructions
·Check for damage on the input and output cables (inspect before charging or use);
·Check for damage on the charger output plug (inspect before charging or use);
·Promptly replace the relevant parts if damage is found. (Inspect before charging or use);
·Clean dust and other foreign objects from the charger air inlet and outlet. (Inspect monthly);
·Confirm the charger input circuit breaker is working normally. Contact the store or manufacturer
promptly if any faults are found;
·Disconnect input power before finding out the cause of a fault, and unplug the charging AC input
connector to avoid an electric shock.
6. Codes and information
Code
Information corresponding
to codes
Code
Information corresponding to
codes
F4
Insulation fault
F14
Stop for unauthorized
shutdown
F5
Over-temperature of
output connector
F15
Overvoltage of battery cell
F6
BMS over-temperature
F16
Undervoltage of battery cell
F7
Charging connector fault
F17
Charging overcurrent
F8
Over-temperature of
battery pack
F18
Battery over-temperature
F9
High-voltage relay fault
F19
Abnormal insulation
F10
Check point 2 detection
fault
F20
Connector fault
Содержание XE Series
Страница 62: ...58 F11 Other faults F12 Abnormal current F13 Abnormal voltage...
Страница 73: ...69...
Страница 81: ...77 Maintenance Record Sheet Date Maintenance content Maintenance personnel...