55
2. Electrical parameters
Model
48 V 100 A
80 V 65 A
Rated input voltage
AC380 V ± 15%
Three-phase four-wire voltage
AC380 V ± 15%
Three-phase four-wire voltage
Input grid frequency
50/60 Hz
50/60 Hz
Power factor
≥ 0.99
≥ 0.99
Input power
≤ 5.2 KW
≤ 5.2 KW
Efficiency
≥ 0.92
≥ 0.92
Rated output voltage
48 V
80V
Rated output current
100 A
65A
Rated output power
4.8 KW
4.8 KW
DC output range
18VDC-65VDC
18VDC-65VDC
Output connector
GB125 A or Rema160 A
Male or female connector available
GB125 A or Rema160 A
Male or female connector available
Cooling method
Forced air cooling
Forced air cooling
Working temperature
-20° C - 50° C
-20° C - 50° C
Working humidity
0% - 95%
0% - 95%
IP class
IP20
IP20
Noise
65dB
65dB
Altitude
< 2000 m
< 2000 m
3. Charger wiring installation and minimum AC input power requirements
4. Charging steps:
The charger's input and output power should be connected by qualified professionals. Connect after
unplugging the input socket or disconnecting the circuit breaker.
1) Move the truck near the charger. Make sure the plug and hands are dry before operating.
Model
Input circuit sectional area (mm)
Air-break switch model
48 V 100 A
3 × 2.5 mm2 + 1 × 2.5 mm2
3P + PE
32A - 3P
80 V 65 A
3 × 2.5 mm2 + 1 × 2.5 mm2
3P + PE
32A - 3P
Содержание XE Series
Страница 62: ...58 F11 Other faults F12 Abnormal current F13 Abnormal voltage...
Страница 73: ...69...
Страница 81: ...77 Maintenance Record Sheet Date Maintenance content Maintenance personnel...