MINIVATOR SIM INSTALLATION MANUAL
27
E
N
G
L
IS
H
Code:
C
Meaning: Description:
IR address fail. The IR address (dip switch)
does not match.
C
Appendix 1
Code:
9
Meaning: Description:
Up direction – Left hand.
Shows when toggle switch
Down direction – Right hand. is activated in down/up direction.
Telephone fault finding action:
None.
On site fault finding action:
None.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Reprogram handsets.
Code:
A
Meaning: Description:
Hinge is open.
A
Telephone fault finding action:
None.
On site fault finding action:
None.
Code:
b
Meaning: Description:
Switch active. A switch is active at power on
i.e. Toggle Up, Toggle down,
IR up IR down or learn.
Telephone fault finding action:
Send engineer.
On site fault finding action:
A short circuit has occurred on toggle circuit – check circuit.
Code:
8
Meaning: Description:
Up direction – Right hand. Shows when toggle switch
Down direction – Left hand. is activated in up/down direction.
8
Telephone fault finding action:
None.
On site fault finding action:
None.
Code:
7
Meaning: Description:
Low voltage. Batteries approaching critical level.
7
Telephone fault finding action:
Ask client to drive lift to charge contacts – if ‘Okay’ code does not
show send engineer. If the lift will not drive – send engineer.
On site fault finding action:
Drive lift to charge contacts. Check charging circuit if ‘Okay’ code not
displayed. If lift will not drive replace batteries and check charging circuit.
5
6
Code:
6
Meaning: Description:
Bot pressure – Right hand. Safety edge (down/up direction)
Top pressure – Left hand. activated – footplate, underpan.
Telephone fault finding action:
Ask client to tap footplate edges. If this does not correct the fault
– send engineer.
On site fault finding action:
Check footplate bottom and downside and chassis underpan.
Code:
5
Meaning: Description:
Bot stop – Right hand. End limits activated.
Top stop – Left hand.
Telephone fault finding action:
Ask client to tap trunnion guards in case they are stuck.
If this does not correct the fault – send engineer.
On site fault finding action:
Check end limit circuit and trunnion guards.
05029 Sim Install MULTI ENG:Layout 1 17/06/2010 14:47 Page 27