28
MINIVATOR SIM INSTALLATION MANUAL
Code:
L
Meaning: Description:
Current limit exceeded.
Code:
H
Meaning: Description:
Relay not open The main power relay
(pre delay). is closed early.
Code:
F
Meaning: Description:
Brake semi-conductor failed.
Code:
E
Meaning: Description:
Relay not closed. The main power relay did not close.
Code:
g
Meaning: Description:
Brake not connected.
Code:
J
Meaning: Description:
Hinge interlock switch error.
Code:
n
Meaning: Description:
Half speed.
F
H
L
L
E
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Telephone fault finding action:
Check client understands loading limits.
Send engineer if persistent fault.
On site fault finding action:
Check motor and track for obstructions.
Telephone fault finding action:
Send engineer if permanently showing unless SlideTrack is installed.
On site fault finding action:
Check reed switches and dip switch settings.
Check battery voltage.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace hinge interlock roller switch.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check brake.
Appendix 1
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check battery voltage and replace if necessary,
otherwise replace main board.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code:
d
Meaning: Description:
Relay not open The main power relay
(stopped). is welded closed.
05029 Sim Install MULTI ENG:Layout 1 17/06/2010 14:47 Page 28