6
3. Description Of Main Components
Structure
Panels and base are made from galvanized steel plate painted with epoxy powder to ensure total resistance to
atmospheric pollution, condensate collection pan as standard.
Air cooled coils:
The coils are made from high performance and seamless copper tuber and high surface area aluminum fins to
ensure optimum heat exchange capability. Condenser coil protection grill is standard.
Fan motor:
To achieve high efficiency heat exchange, the unit is equipment with the high performance axial-flow fans. The fan
is driven directly by weather proof motor to ensure reliable operation, the fan motor is six-pole electric motor with
built-in thermal cut-out.
Hydraulic module:
It is fully integrated and equipped with key hydraulic components such as plate-heat exchanger and water
circulating pump.The water pressure difference switch is provided in the units to protect against damage to the
water pump.
Power and control electrical panel
Power and control electrical panel constructed in accordance with IEC 204-1/EN60335-2-40, complete with
compressor contactor,control via control panel.
AW042SSCHA AW062SSCHA
1. Compressor
2. Gas liquid separator
3. Electronic expansion valve
4. 4-way valve
5. High pressure switch
6. High pressure sensor
7. Low pressure sensor
8. Condenser
9. Motor
10. Fan
11. Accumulator
12. Electrical panel
Содержание HU062WAMNA
Страница 1: ...ATW Split Service Manual SYJS 2022 A Edition 2022 A ...
Страница 16: ...16 6 Piping Diagram ...
Страница 25: ...25 Cooling Tao C Two C Ta Ambient temperature Two Outlet water temperature ...
Страница 79: ...79 No Drawing Name of parts Quantity 1 Drainage elbow 4 2 Rubber cushion 4 Accessories ...