Page 71
The 4 (SAY) key allows the controller to say the selected voice message over a speaker. This voice message can be an audible
reminder of special events and occasions (i.e. "Front Door Open" when the front door is opened).
The 5 (PHONE) key allows the controller to call the selected phone number and say the selected voice message.
The 6 (SEND) key allows you to send any a text messages through the Pro-Link serial port.
Program Video Commands*
This program command is used to display video automatically on an OmniTouch with Video touchscreen when an event occurs.
You can specify which camera and which touchscreen(s) will display the video when the event takes place. When the event takes
place, it switches each of the specified touchscreens to full screen video.
* This item can only be programmed via PC Access.
Edit Program Condition
Selecting the 3 (&COND) key, from the
Edit Program
menu, allows the condition for the program to be specified. The condition
is optional in all program lines. This condition must be true when the program time or event occurs for the program to executed.
Note:
Two (2) conditions can be specified in each program line; however, when programming from the keypad, only 1 condition
can be selected. If 2 conditions must be specified for a single program line, it must be entered using the PC Access Software.
When 2 conditions are part of a single program, the conditions are not displayed on the keypad. Instead, "&MULTI" is displayed
to let you know that this program line contains 2 conditions. To view or edit the program, you must use the PC Access Software.
The following menu is displayed:
SELECT
CONDITION
1=CTRL 2=MODE 3=ZONE
↓
9=TIME #=MISC
↑
After the condition is specified, the display returns to the
Edit Program
menu.
Program Control Conditions
Press the 1 (CTRL) key to specify that the program should only execute if a specified control unit is either On or Off.
The display prompts for the unit number:
UNIT:
ENTER UNIT
↓
Enter the unit number followed by the ' # ' key, or use the arrow keys to select the unit. The unit is displayed and the display
prompts for the state of the unit:
IF Porch Light:
0=OFF
1=ON
Program Lumina Mode Conditions
Press the 2 (MODE) key to specify that the program should only execute if Lumina is currently set to the desired mode. Select
the Lumina mode from the following menu:
1
=HOME 2=SLEEP 3=AWAY
4=VACAT
5=PARTY
6=SPEC
Next, select whether the system is considered in the specified mode during the “Mode Change Delay”: