APPENDIX B – HLC PLANNER
It is very important to plan each Room by filling in the worksheets for each Room.
When filling in the worksheet, put a check in the box under “HLC Device Type” for each unit in the room, then:
You should assign a name to the following HLC devices:
¾
Room Controllers that resides on the 1
st
unit in each Room (i.e. Unit 1, 9, 17, 25, etc.)
¾
Lighting Loads (Dimmers and Switches) in each Room
You should not assign a name to the following HLC devices:
∅
Room Controllers that reside between the 2
nd
and 7
th
unit in a Room
∅
House Controllers that reside on the 8
th
unit in a Room
∅
Lumina Mode Controllers that reside on the 8
th
unit in a Room
Lumina can have up to 8 Rooms of HLC Lighting.
In this example, Room 1 is the Living Room. The Living Room consists of 2 Room Controllers (one at each entry into the Living
Room), 5 Lighting Loads, and 1 House Controller (which controls up to 8 Rooms).
ROOM 1: Living Room
Unit
Unit Number
HLC Device Type
Name
1st
Unit 1
;
Room Controller
Living Room
2nd
Unit 2
Lighting Load
;
Room Controller
3rd
Unit 3
;
Lighting Load
Room Controller
-Cans
4th
Unit 4
;
Lighting Load
Room Controller
-Chandelier
5th
Unit 5
;
Lighting Load
Room Controller
-Sconce
6th
Unit 6
;
Lighting Load
Room Controller
-Spot Lights
7th
Unit 7
;
Lighting Load
Room Controller
-Table Lamp
8th
Unit 8
Lighting Load
;
House
Mode
Room 2 is the Kitchen. The Kitchen consists of 1 Room Controller, 6 Lighting Loads, and one Lumina Mode Controller.
ROOM 2: Kitchen
Unit
Unit Number
HLC Device Type
Name
1st
Unit 1
;
Room Controller
Kitchen
2nd
Unit 2
;
Lighting Load
Room Controller
-Breakfast
3rd
Unit 3
;
Lighting Load
Room Controller
-Cans
4th
Unit 4
;
Lighting Load
Room Controller
-Cabinets
5th
Unit 5
;
Lighting Load
Room Controller
-Sink
6th
Unit 6
;
Lighting Load
Room Controller
-Island
7th
Unit 7
;
Lighting Load
Room Controller
-Ovrhd Lghts
8th
Unit 8
Lighting Load
House
;
Mode