APS-7000 Series User Manual
22
Line Voltage
Input
APS-7050
115 / 230V
15%
50 / 60Hz
1.8kVA MAX.
Voltage Input: 115/230±15% VAC;
Line frequency: 50Hz/60 Hz
(Automatically switchable)
APS-7100
OUTPUT
INPUT
L
N
N
L
Voltage Input: 115/230±15%
VAC ; Line frequency:
50Hz/60 Hz (Automatically
switchable)
APS-7200 & 7300
N
L
Voltage Input: 230±15% VAC ;
Line frequency: 50Hz/60 Hz
Rear Voltage
Output Socket
Output voltage terminal.
APS-7050
L
N
OUTPUT
APS-7100
OUTPUT
INPUT
L
N
N
L
APS-7200 & 7300
L
N
Sync Output
Socket
SYNC
BNC socket. This socket will output a
signal of approximately 10V when the
output is on.
Signal Output
Signal output
APS-7050
APS-7100
APS-7200
APS-7300
Connector for monitoring PASS, FAIL
and PROCESSING output signals
when using the Program mode.
Remote Control
Trigger Out
Trigger In
Out On / Off
COM
APS-7200 and APS-7300
Trigger Out
Trigger In
Out On / Off
COM
APS-7050 and APS-7100
Connector for controlling the
TRIGGER IN, TRIGGER OUT and
OUT ON/OFF states.
Содержание APS-7000 Series
Страница 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 25: ...GETTING STARTED 25 Indicates that the panel lock is active ARB Indicates that the ARB function is active ...
Страница 89: ...OPERATION 89 Exit 4 Press Exit F4 to exit from the MISC Configuration settings Example Settings ...
Страница 111: ...OPERATION 111 Simulate Example ...
Страница 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Страница 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Страница 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Страница 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Страница 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...