OPERATION
143
System
Configuration
Screen Overview
Test mode
System Conf
Save/Recall
Run test
Contrast
Loop
Timer Unit
Alarm
Single Step
Run Mode
V-limit
F-limit
Phase
Power Up
Results
Surge Dip
OC Fold
System
Configuration
Parameters
The System Configuration screen is accessible
when the
System Config[F2]
soft-key is pressed.
Run Mode
When set to “MANUAL” mode, only
Memory number, VSET, FSET, H-
IRMS(A), SD-VOLT, SD-SITE,
SD_CONT and SD-TIME will be
enabled.
When set to “PROGRAM” mode, all
the parameters are available.
Single Step Sets the program to run only one
step at a time. After a step is run
the program is held until the
Output key is pressed, after which
the program will go to the next step.
Alarm
Turns the alarm buzzer on/off.
Power Up
When this option is turned on, the
current program will be loaded and
run after APS-7000 powers up.
Содержание APS-7000 Series
Страница 1: ...Programmable AC Power Source APS 7000 Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 25: ...GETTING STARTED 25 Indicates that the panel lock is active ARB Indicates that the ARB function is active ...
Страница 89: ...OPERATION 89 Exit 4 Press Exit F4 to exit from the MISC Configuration settings Example Settings ...
Страница 111: ...OPERATION 111 Simulate Example ...
Страница 157: ...COMMUNICATION INTERFACE 157 Exit 6 Press Exit F4 to exit from the serial port settings ...
Страница 187: ...APPENDIX 187 APS 7000 Dimensions APS 7050 402 545 5 430 110 4 87 9 Scale mm ...
Страница 188: ...APS 7000 Series User Manual 188 APS 7100 561 6 705 5 430 110 4 87 9 Scale mm ...
Страница 189: ...APPENDIX 189 APS 7200 402 5 310 5 429 8 682 4 649 2 Scale mm ...
Страница 190: ...APS 7000 Series User Manual 190 APS 7300 491 5 399 5 429 8 682 4 649 2 Scale mm ...